BLOG main image
분류 전체보기 (781)
LENOVO (19)
HP (3)
DELL (7)
IBM (32)
My Retain Tip (697)
자료실 (0)
Firmware (5)
기타서버관련소식 (5)
IBM Server Picture (3)
STUDY (2)
설정세팅 (0)
Visitors up to today!
Today hit, Yesterday hit
daisy rss
tistory 티스토리 가입하기!
2018. 8. 18. 10:17
Notice!!
IBM
본 블로그의 모든내용은 ibm.com에 있는 내용이며 본 블로그의 내용은 증빙내용으로는 활용 불가능합니다
주의! 모든 방문자는 공지를 반드시 읽어본 후 글을 읽으시기 바랍니다.:*필독공지*

딴지 거실분들은 절대 읽지 마시고 100% 정확한 정보가 있는 ibm.com 에서 확인하시기 바랍니다.

SR950 LENOVO SITE : https://lenovopress.com/lp0647-thinksystem-sr950-server

Lenovo ThinkSystem SR950 Server

한글메뉴얼

 

sr950_setup_guide.pdf

 

 

-파트리스트 링크(partlist)

https://datacentersupport.lenovo.com/kr/ko/products/servers/thinksystem/sr950/7x13/parts

 

 

Introduction

Lenovo ThinkSystem SR950 is designed for your most demanding, mission-critical workloads, such as in-memory databases, large transactional databases, batch and real-time analytics, ERP, CRM, and virtualized server workloads. The powerful 4U ThinkSystem SR950 can grow from two to eight Intel Xeon Scalable Family processors, and with 96 DIMM sockets, supports up to 12 TB of high-speed memory. The modular design of SR950 speeds upgrades and servicing with easy front or rear access to all major subsystems to maximize server availability.

The SR950 packs numerous fault-tolerant and high-availability features into a high-density, 4U rack-optimized design that reduces the space needed to support massive network computing operations and simplify servicing.

The following figure shows the Lenovo ThinkSystem SR950.

Lenovo ThinkSystem SR950
Figure 1. Lenovo ThinkSystem SR950

Did you know?

The SR950 server supports up to eight processors in a single 4U chassis. You can upgrade from a 2-socket system to an 8-socket system without having to replace the server enclosure or upgrade to a physically larger design. The SR950 offers enterprise scalability and advanced RAS features to support the most demanding mission-critical applications that require 24x7 operations.

Key features

Lenovo ThinkSystem SR950 is designed for your most demanding, mission-critical workloads, such as in-memory databases, large transactional databases, batch and real-time analytics, ERP, CRM, and virtualized server workloads. The powerful 4U ThinkSystem SR950 can grow from two to eight Intel Xeon Processor Scalable Family CPUs, achieving up to 45% faster performance than the previous generation. The modular design of SR950 speeds upgrades and servicing with easy front and rear access to all major subsystems, to maximize server uptime.

Scalability and performance

The SR950 offers numerous features to boost performance, improve scalability, and reduce costs:

  • Dense server offering where up to 8 processors and 96 DIMMs are housed in only 4U of rack space.
  • Offers a simple upgrade path that enables the server to be initially configured with as few as two processors and then later be upgraded to up to eight processors simply by adding a compute tray and system boards.
  • Supports the Gold and Platinum level processors in the Intel Xeon Processor Scalable Family, including the "top bin" highest-performing 205 W processors available from Intel.
  • Up to eight processors, each with up to 28 cores and 56 threads (for a total of up to 448 threads) to maximize the concurrent execution of multithreaded applications.
  • Intelligent and adaptive system performance with Intel Turbo Boost Technology 2.0 allows processor cores to run at maximum speeds during peak workloads by temporarily exceeding processor TDP.
  • Intel Hyper-Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core, up to two threads per core.
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Support for up to 96 TruDDR4 DIMMs operating at 2666 MHz means you have the fastest available memory subsystem and memory capacity of up to 12 TB using 96x 128 GB 3DS RDIMMs.
  • Up to 24x 2.5-inch HDDs or SSDs provide a flexible and scalable all-in-one platform to meet your increasing demands.
  • Of the 24x drive bays, support for up to 12 NVMe PCIe SSDs maximizes drive I/O performance, in terms of throughput, bandwidth, IOPS, and latency.
  • The use of solid-state drives (SSDs) instead of, or along with, mechanical hard disk drives (HDDs), can improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • New high-speed RAID controllers provide 12 Gb SAS connectivity to the drive backplanes. A variety of RAID adapters are available, with cache up to 4 GB and support for 12 drives on a single controller.
  • Supports a new Lenovo-patented M.2 adapter design for convenient operating system boot functions. Available M.2 adapters support either one M.2 drive, or two M.2 drives in a RAID 1 configuration, for the boot drive performance and reliability.
  • The server has a dedicated flexible LAN-on-motherboard (LOM) slot offering a variety of 10 GbE or Gigabit Ethernet adapters that do not occupy one of the standard PCIe slots.
  • A total of up to 17 rear-accessible PCIe slots: 14 general-purpose PCIe 3.0 slots plus slots dedicated to the LOM adapter and two ML2 adapters. In addition, the server has two internal slots for RAID or HBA adapters.
  • The server offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by almost 100% (8 GTps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GTps per link using 8b/10b encoding).

Availability and serviceability

The SR950 is based on a modular service model where all components and options can be removed from the front or rear of the system, even parts that are located in the center of the machine such as fans, memory DIMMs, and processors.

Watch the following video to show how easy it is to service the SR950 server:
https://lenovopress.com/lp0899-thinksystem-sr950-ease-of-service-video

The SR950 provides many features to simplify serviceability and increase system uptime:

  • The server offers Single Device Data Correction (SDDC, also known as Chipkill), Adaptive Double- Device Data Correction (ADDDC, also known as Redundant Bit Steering or RBS), memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • The server offers hot-swap drives, supporting RAID redundancy for data protection and greater system uptime.
  • The Dual M.2 Boot Adapter uses RAID-1 so that the two M.2 drives installed are configured as a redundant pair.
  • The server has up to four hot-swap N+N redundant power supplies to help keep the server operational in the event of a power supply or utility supply failure
  • Each compute tray has 6 hot-swap N+1 redundant fans (a total of 12 fans when two compute trays are installed) to maximize availability for business-critical applications.
  • The power source-independent light path diagnostics functionality provides individual light path LEDs that lead the technician to failed (or failing) components, which simplifies servicing, speeds up problem resolution, and helps increase system availability.
  • The included LCD system information display panel provides greater diagnostic function by listing all error messages and VPD data needed for a service call, thereby speeding problem resolution and increasing system uptime.
  • Proactive Platform Alerts (including PFA and SMART alerts): Processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs, NVMe SSDs, M.2 storage, and flash storage adapters), fans, power supplies, RAID controllers, and server ambient and subcomponent temperatures. Alerts can be surfaced through the XClarity Controller to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
  • Solid-state drives (SSDs) offer more reliability than mechanical HDDs for greater uptime.
  • The built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
  • Lenovo XClarity Provisioning Manager supports diagnostic functions and collects service data to USB key drive or remote CIFS share folder for troubleshooting, to reduce servicing time.
  • Autorestart in the event of a momentary loss of AC power (based on power policy setting in the XClarity Controller service processor)
  • Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
  • Three-year or one-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Manageability and security

Powerful systems management features simplify local and remote management of the SR950:

  • The server includes an XClarity Controller (XCC) to monitor server availability and perform remote management. XCC Enterprise is included as standard, which enables remote KVM and remote media files (ISO and IMG image files), boot capture, and power capping.
  • Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
  • Support for Lenovo XClarity Energy Manager which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
  • Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Supports Secure Boot to ensure that only a digitally signed operating system can be used. Supported with HDDs and SSDs as well as M.2 drives in the M.2 Adapter.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
  • Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.

Energy efficiency

The SR950 offers the following energy-efficiency features to save energy, reduce operational costs, and increase energy availability:

  • The server can be used in environments up to ASHRAE A4 with ambient temperatures up to 45 °C.
  • The server is Energy Star 2.1 compliant
  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum certifications
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed, to reduce energy draw.
  • Low-voltage 1.2 V DDR4 memory offers energy savings compared to 1.35 V and 1.5 V DDR3 DIMMs.
  • Solid-state drives (SSDs) consume as much as 80% less power than mechanical 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system.
  • Optional Lenovo XClarity Energy Manager provide advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.

Components and connectors

The following figure shows the front of the SR950 server.

Front view of the Lenovo ThinkSystem SR950
Figure 2. Front view of the Lenovo ThinkSystem SR950

The following figure shows the rear of the SR950 server. The server has up to 17 PCIe slots, depending on the riser cards selected and the number of processors installed.

Rear view of the Lenovo ThinkSystem SR950
Figure 3. Rear view of the Lenovo ThinkSystem SR950

The processors and other components are located on compute trays, the Upper Compute Tray and the Lower Compute Tray. Each compute tray holds up to four processors on two system boards. The compute trays are accessible from the front of the server, as shown in the following figure.

ThinkSystem SR950 with Lower Compute Tray partially removed
Figure 4. Lower Compute Tray partially removed

The server has one or two compute trays. Each compute tray contains:

  • One or two compute system boards, each comprising:
    • Two processors
    • 24 DIMMs
  • Six hot-swap fans, accessible even when the compute tray is installed
  • 12x 2.5-inch hot-swap drive bays
  • One PCIe slot reserved for a RAID adapter for internal SAS/SATA drives

The following figure shows the rear of the compute tray with its two compute system boards, one of them removed.

SR950 compute tray with two compute system boards
Figure 5. Compute tray with two compute system boards

The compute system board is shown in the following figure. Each system board holds two processors and 24 DIMM sockets, 12 per processor. The system board also has connections for the NVMe ports used to connect to the PCIe NVMe drive bays at the front of the server.

ThinkSystem SR950 Compute System Board
Figure 6. Compute system board

Processors installed in the compute system boards are numbered as shown in the following figure.

Processor numbering
Figure 7. Processor numbering (viewed from the rear of the compute trays)

For some four-socket storage-rich configurations, a storage tray is used in the upper tray area instead of a compute tray. The following figure shows the key components of the storage tray.

Storage tray
Figure 8. Storage tray

All slots and ports at the rear of the server are housed in the I/O tray as shown in the following figure.

I/O tray
Figure 9. I/O tray

Server configurations

The SR950 supports five different configurations, depending on the desired number of processors, drive bays, PCIe slots, and upgradability to an 8-socket configuration.

Notes:

  • The configurations listed here represent Lenovo's recommendations regarding the selection of compute system boards, I/O riser cards, and NVMe drive bays to maximize the available resources. You can select fewer drives and lower slot counts by using lower-slot-count riser cards to meet application requirements.
  • The use of only two, three or six processors in configurations where supported will reduce the available I/O slots and NVMe drive bays. This is described in details in the Internal storage section and the I/O expansion options section.
  • Configurations 1 and 2 support either two, three or four processors however the use 5100 Series processors requires that four processors be selected. Two or three 5100 Series processors are not supported in these configurations due to the way the processors are connected.
  • Configurations 3 and 4 are designed to be easily upgradable to 8 processors. As a result, 8100 Series processors are required.

When building a server in the configurator, the feature codes in the following table are key to selecting the right configuration.

Table 1. Feature codes for selecting base server configurations
Part number Feature code Description
CTO only AUNY SR950 2S to 4S Base (Upgrade to 8S using the 4S Performance to 8S Upgrade Kit)
CTO only AUKF SR950 2S to 8S Base (Simple upgrade without needing the upgrade kit
CTO only AX3Y 12 Hard Drive Maximum System
CTO only AX3Z 24 Hard Drive Maximum System

Upgrades: Configurations 1-4 can be upgraded to an 8-socket configuration (Configuration 5) as described in the Server configuration upgrades section.

Table 2. Server configurations
Server Configuration 1

Configuration 1. Four-Socket Performance

The highest-performing 4-socket server, at the lowest cost when up to 12 drives is enough and without the need for a simple upgrade.

  • Supports 2, 3 or 4 processors (if using 5100 Series processors, 4 processors must be selected)
  • 4 sockets configured in mesh topology for best performance
  • 12 drive bays, 6 of which support NVMe drives (4 NVMe with 3 processors and 2 NVMe with 2 processors)
  • 15 rear PCIe slots with 4 processors (10 rear slots with 3 processors, 6 rear slots with 2 processors)
  • Filler installed in the upper tray area
  • Can be upgraded to 8S but requires the 4S Performance to 8S Upgrade Kit, additional components, and Lenovo hardware installation.
  • Select feature codes AUNY and AX3Y
Server Configuration 2

Configuration 2. Four-Socket Performance/ Storage Rich

The highest-performing 4-socket server, when needing more than 12 drives without the need for a simple upgrade.

  • Supports 2, 3 or 4 processors (if using 5100 Series processors, 4 processors must be selected)
  • 4 processors configured in mesh topology for best performance
  • 24 drives, 12 of which support NVMe drives (8 NVMe with 3 processors, 4 NVMe with 2 processors)
  • 13 rear PCIe slots with 4 processors (9 rear slots with 3 processors, 5 rear slots with 2 processors)
  • Storage tray installed in the upper tray area
  • Can be upgraded to 8S but requires the 4S Performance to 8S Upgrade Kit, additional components, and Lenovo hardware installation.
  • Select feature codes AUNY and AX3Z
Server Configuration 3

Configuration 3. Four-Socket Upgradable

The lowest-cost 4-socket server capable of a simple upgrade to 8 socket and when 12 drive bays with 4 processors is enough storage.

  • 2 or 4 processors, must be 8100 Series processors
  • 4 processors in a ring topology
  • 12 drive bays including up to 6 NVMe (2 NVMe with 2 processors)
  • Up to 15 rear PCIe slots with 4 processors (6 rear slots with 2 processors)
  • Filler installed in the upper tray area
  • Upgradable to 8-socket with an additional compute tray and two system boards
  • Once upgraded, the system will have 24 drive bays
  • Select feature codes AUKF and AX3Y
Server Configuration 4

Configuration 4. Four-Socket Upgradable / Storage Rich

4-socket server capable of a simple upgrade to 8-socket and needing more than 12 drive bays with 4 processors.

  • Requires 4 processors, must be 8100 Series
  • 4 processors in a ring topology
  • 24 drive bays (including up to 4 NVMe)
  • 10 rear PCIe slots
  • Two compute trays, with one system board in each tray
  • Upgradable to 8-socket with two additional system boards
  • Once upgraded, the server will support 12 NVMe drives.
  • Select feature codes AUKF and AX3Z
Server Configuration 5

Configuration 5. Eight-Socket Storage Rich

Full featured 6- or 8-socket server with up to 24 drive bays and the maximum number of PCIe x16 slots.

  • Requires 6 or 8 processors, must be 8100 Series
  • 24 drive bays, 12 of which support NVMe drives (8 NVMe with 6 processors)
  • 17 rear PCIe slots (13 rear slots with 6 processors installed)
  • Two compute trays each with two system boards
  • Select feature codes AUKF and AX3Z

The following table summarizes the configurations.

Table 3. SR950 server configurations
Configuration Supported
processors
Lower Tray Upper Tray Processor
Topology
Maximum
storage
Maximum
PCIe slots
Upgrade to 8S?
4S Performance 2 or 4
Any processor†
Compute Tray Filler 4S Mesh* 12 drives
(6 NVMe)
15 Yes‡
4S Performance/
Storage Rich
4
Any processor
Compute Tray Storage Tray 4S Mesh* 24 drives
(12 NVMe)
13 Yes‡
4S Upgradable 2 or 4
8100 Series only
Compute Tray Filler 4S Ring 12 drives
(6 NVMe)
15 Yes**
4S Upgradable/
Storage Rich
4
8100 Series only
Compute Tray
with 1 system board
Compute Tray
with 1 system board
4S Ring 24 drives
(4 NVMe)
10 Yes**
8S Storage Rich 8
8100 Series only
Compute Tray Compute Tray 8S 24 drives
(12 NVMe)
17 Not applicable

† If using 5100 Series processors, then 4 processors must be selected. Using two 5100 Series processors is not supported.
* Mesh topology requires a processor with 3 UPI connections; Processors such as the 5100 series with only 2 UPI connections will operate in Ring topology. See the table in the Processor options section.
‡ Upgrade requires the ThinkSystem SR950 4S Performance to 8S Upgrade Kit, 4TA7A10969. See the Server configuration upgrades section below.
** After upgrade, maximum storage will be 24 drives (12 NVMe) and up to 17 total PCIe slots available (may require replacement riser cards)

For details about PCIe slot availability based on each server configuration, see Slot availability by server configuration.

Server configuration upgrades

This section describes the system upgrades you can perform in the field. The upgrades are based on the configurations that are described in the Server configurations section.

Key components in the upgrades are listed in the following table.

Table 4. System upgrades
Part number Feature code Description
4TA7A10969 Various ThinkSystem SR950 4S Performance to 8S Upgrade Kit
7XG7A03955 AUN0 ThinkSystem SR950 2-CPU, 24 DIMM Compute System Board
7XG7A03956 Various ThinkSystem SR950 Upper Compute Tray Kit

4S Performance to 8S Upgrade Kit, 4TA7A10969, includes the following components:

  • 4 mid-plane UPI & sideband interconnects

The Compute System Board option, 7XG7A03955, includes the following components:

  • One compute system board, without processors or memory

The Upper Compute Tray Kit, 7XG7A03956, includes the following components:

  • 1x compute tray with 12 drive bays and 1 slot for storage adapter
  • 1x compute system board
  • 3x 4-bay drive bay fillers

Note: The Upper Compute Tray Kit does not include drive backplanes

The following table describes the before and after configurations and the components you will need to order to achieve the desired configuration.

Table 5. Upgrades to Server configurations (See Server configurations section for configuration definitions)
Initial configuration Desired upgraded configuration Parts to order and install
Configuration 1
(Four-Socket Performance)
2 processors installed
Configuration 1
(Four-Socket Performance)
4 processors installed
  • 1x Compute System Board, 7XG7A03955
  • 2x processor options (match installed)
  • Memory DIMMs (matching installed is recommended)
Configuration 1
(Four-Socket Performance)
3 processors installed
Configuration 1
(Four-Socket Performance)
4 processors installed
  • 1x processor option (match installed)
  • Memory DIMMs (matching installed is recommended)

Configuration 1
(Four-Socket Performance)
4 processors installed

(including SAP HANA models and configurations)

Configuration 5
(Eight-Socket Storage Rich)
8 processors installed
  • 1x 4S Performance to 8S Upgrade Kit, 4TA7A10969
  • 1x Upper Compute Tray Kit, 7XG7A03956*
  • 1x Compute System Board, 7XG7A03955
  • 4x 81xx processor options (match installed)**
  • Memory DIMMs (matching installed is recommended)
  • Drive backplanes for upper compute tray
  • RAID adapter or HBA for upper compute tray
  • Drives for upper compute tray
  • Additional/replacement PCIe riser cards
  • Lenovo Basic Hardware Installation services

Configuration 2
(Four-Socket Performance/ Storage Rich)
4 processors installed

(including customized SAP HANA models)

Configuration 5
(Eight-Socket Storage Rich)
8 processors installed
Configuration 2
(Four-Socket Performance/ Storage Rich)
2 processors installed
Configuration 2
(Four-Socket Performance/ Storage Rich)
4 processors installed
  • 1x Compute System Board, 7XG7A03955
  • 2x processor options (match installed)
  • Memory DIMMs (matching installed is recommended)
Configuration 2
(Four-Socket Performance/ Storage Rich)
3 processors installed
Configuration 2
(Four-Socket Performance/ Storage Rich)
4 processors installed
  • 1x processor option (match installed)
  • Memory DIMMs (matching installed is recommended)
Configuration 3
(Four-Socket Upgradable)
2 processors installed
Configuration 3
(Four-Socket Upgradable)
4 processors installed
  • 1x Compute System Board, 7XG7A03955
  • 2x processor options (match installed)
  • Memory DIMMs (matching installed is recommended)
Configuration 3
(Four-Socket Upgradable)
4 processors installed
Configuration 5
(Eight-Socket Storage Rich)
8 processors installed
  • 1x Upper Compute Tray Kit, 7XG7A03956*
  • 1x Compute System Board, 7XG7A03955
  • 4x 81xx processor options (match installed)*
  • Memory DIMMs (matching installed is recommended)
  • Drive backplanes for upper compute tray
  • RAID adapter or HBA for upper compute tray
  • Drives for upper compute tray
  • Additional/replacement PCIe riser cards
Configuration 4
(Four-Socket Upgradable / Storage Rich)
4 processors installed
Configuration 5
(Eight-Socket Storage Rich)
8 processors installed
  • 2x Compute System Board, 7XG7A03955
  • 4x 81xx processor options (match installed)**
  • Memory DIMMs (matching installed is recommended)
  • Additional/replacement PCIe riser cards
Configuration 5
(Eight-Socket Storage Rich)
6 processors installed
Configuration 5
(Eight-Socket Storage Rich)
8 processors installed
  • 2x processor option (match installed)
  • Memory DIMMs (matching installed is recommended)

* The Upper Compute Tray Kit includes 1x Compute System Board
** 8-socket configurations must use Intel Xeon Platinum (81xx) processors

Configuration notes:

  • The added processors must match the processors already installed.
  • When upgrading to Configuration 5 (8-socket configuration), Platinum-level (81xx) processors must be used, as listed in the Processor options section. Gold processors do not support 8-socket configurations.
  • For best performance, each processor added should match the memory configuration of existing processors (number & size of DIMMs)
  • The ThinkSystem SR950 4S Performance to 8S Upgrade Kit, 4TA7A10969, contains the mid-chassis interconnects needed for an 8-socket configuration, replacing the existing interconnects. Lenovo installation is highly recommended due to the complexity of this upgrade. Installation cost will vary depending on location and scope of work.

Standard specifications

The following table lists the standard specifications.

Table 6. Standard specifications
Components Specification
Machine type 7X11 - 1-year warranty
7X12 - 3-year warranty
7X13 - SAP HANA configurations with 3-year warranty
Form factor 4U rack
Processor

Up to eight Intel Xeon Processor Scalable Family of processors, either Gold or Platinum level processors (formerly codename "Skylake"). Supports processors with up to 28 cores, core speeds up to 3.6 GHz, and TDP ratings up to 205W.

Processors and memory are located on system boards installed in compute trays: 2 processors per system board, 2 system boards per compute tray, and 2 compute trays in the server.

Chipset Intel C624 chipset (formerly codename "Lewisburg")
Memory Up to 96 DIMM sockets (12 DIMMs per processor, installed on each system board). Lenovo TruDDR4 RDIMMs, LRDIMMs and 3DS RDIMMs are supported. Each processor has 6 memory channels, with 2 DIMMs per channel
Memory maximums

With RDIMMs: Up to 3 TB with 96x 32 GB RDIMMs and eight processors
With LRDIMMs: Up to 6 TB with 96x 64 GB LRDIMMs and eight processors
With 3DS RDIMMs: Up to 12 TB with 96x 128 GB 3DS RDIMMs and eight processors

Note: Support of more than 768 GB per processor (more than 3 TB for a 4-processor system or 6 TB for an 8-processor system) requires M-suffix processors with 1.5 TB memory support. See the Processor options section for information.

Memory protection ECC, SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs), memory mirroring, and memory sparing.
Disk drive bays Up to 24x 2.5" hot-swap SAS/SATA drive bays. With AnyBay backplanes, 12 bays can be configured to support PCIe NVMe drives.
Maximum internal storage Up to 184.3 TB with 24x 7.68 TB 2.5-inch SAS SSDs or
Up to 48 TB with 24x 2 TB 2.5-inch NL SAS HDDs
Storage controller
  • No embedded RAID
  • 12 Gb SAS/SATA RAID adapters:
    • RAID 530i (cacheless) supports RAID 0, 1, 10, 5, 50
    • RAID 730-8i with 1GB cache supports RAID 0, 1, 10, 5, 50
    • RAID 930-8i with 2GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
    • RAID 930-16i with 4GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
  • 12 Gb SAS/SATA non-RAID: 430-8i and 430-16i HBAs
Optical and tape bays No internal bays.
Network interfaces Integrated 10Gb Ethernet controller, based on the Intel Ethernet Connection X722. The server supports 1 of 6 available LOM adapters, providing either 2- or 4-port Gigabit Ethernet, 2- or 4-port 10 GbE with SFP+ connections or 2- or 4-port 10 GbE with RJ45 connections. One port can optionally be shared with the XClarity Controller (XCC) management processor for Wake-on-LAN and NC-SI support. 1 or 2 ML2 adapter slots for additional network adapters.
PCI Expansion slots

Up to 17 PCIe 3.0 rear-accessible slots:

  • Slots 1-4 on a riser, one of:
    • Riser with 4x PCIe 3.0 x16 slots, all full-height half-length, all 75W
    • Riser with 2x PCIe 3.0 x16 slots, all full-height half-length, both 75W
    • Riser with 4x PCIe 3.0 x8 slots, full-height half-length, all 75W
  • Slot 5: PCIe 3.0 x16, low-profile, 75W
  • Slot 6: PCIe 3.0 x16, low-profile, 75W
  • Slot 7: PCIe 3.0 x8, low-profile, 75W
  • Slot 8: PCIe 3.0 x16 ML2, low-profile (supports NC-SI)
  • Slot 9: PCIe 3.0 x8 LOM adapter slot, low-profile (supports NC-SI)
  • Slots 10-15 on a riser, one of:
    • Riser 5x16+ML2:
      • Five PCIe 3.0 x16 slots, all full-height half-length, all 75W
      • One PCIe 3.0 x16 ML2 slot, full-height half-length, 30W (no NC-SI support)
    • Riser 2x16: Two PCIe 3.0 x16 slots, all full-height half-length, both 75W
    • Riser 4x8: Four PCIe 3.0 x8 slots, full-height half-length, all 75W
  • Slot 16-17 on a riser:
    • PCIe 3.0 x8 low profile, 75W
    • PCIe 3.0 x8 low profile, 75W

Additional internal PCIe slots:

  • One or two PCIe 3.0 x8 slots for storage adapters
  • M.2 adapter slot
Ports Front: two USB 2.0 ports (one also for XCC local management), and one VGA video port. Rear: two USB 3.0, one VGA video, one DB-9 serial, and one 1 GbE RJ-45 systems management. The serial port can be shared with the XCC for serial redirection functions. Only one VGA port can be used at a time.
Cooling Up to 12 redundant hot-swap single-rotor fans, 6 in each compute tray. Each tray has N+1 fan redundancy.
Power supply Up to four redundant hot-swap 1100 W or 1600 W power supplies (80 PLUS Platinum certified), supporting 200-240 V AC input. The 1100 W power supply also supports 100-127V AC input supply with a reduced capacity of 1050 W. No support for 240 V DC.
Hot-swap parts Drives, power supplies, and fans.
Video G200 graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Security features Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 1.2 or TPM 2.0. In China only, optional Trusted Cryptographic Module (TCM).
Systems management XClarity Controller embedded management, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. XClarity Controller Enterprise functionality standard with the SR950. Light path diagnostics for local failure detection and reporting, with LCD diagnostic pull-out panel.
Operating systems Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating system support section for specifics.
Limited warranty One year or three-year (model dependent) customer-replaceable unit (CRU) and onsite limited warranty with 9x5 next business day (NBD).
Service and support Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
Dimensions Height: 173 mm (6.8 in.); depth EIA flange to rear: 800.0 mm (31.5 in.), depth overall: 835.0 mm (32.9 in.); width across top cover: 447.0 mm (17.6 in.), width to EIA flanges: 482.0 mm (19.0 in.).
Weight Minimum configuration: 32.6 kg (71.9 lb), Maximum configuration: 58.7 kg (129.4 lb)

The server is shipped with the following items:

  • Rail kit
  • Documentation flyer
  • Power cords (model and region dependent)

Models

The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Common to all models:

  • All models include a rail kit.
  • One power cord is included for each power supply configured:
    • All models for India include 2.8m, 10A/250V, C13 to IS 6538 Line Cords
    • For other countries:
      • Models with 1600W power supplies include 2.8m, 10A/100-250V, C13 to C14 Jumper Cords
      • Models with 1100W power supplies include 2.8m, 13A/100-250V, C13 to C14 Jumper Cords

Models for Australia and New Zealand

Table 7. Models for Australia and New Zealand
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A00CAU 4x Gold 5120 14C 105W 2.2GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A00RAU 4x Gold 5120 14C 105W 2.2GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A00SAU 4x Gold 5120 14C 105W 2.2GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A00BAU 2x Gold 6130 16C 125W 2.1GHz 1 2x 32GB 1x RAID 930-8i 8x 2.5" Open Open 5 (0,0,0,0) 2x 1100W HS
7X12 A00FAU 2x Gold 6130 16C 125W 2.1GHz 1 2x 32GB 1x RAID 930-8i 8x 2.5" Open Open 5 (0,0,0,0) 2x 1100W HS
7X12 A00UAU 2x Gold 6130 16C 125W 2.1GHz 1 2x 32GB 1x RAID 930-8i 8x 2.5" Open Open 5 (0,0,0,0) 2x 1100W HS
7X12 A00HAU 4x Platinum 8153 16C 125W 2.0GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A00LAU 4x Platinum 8153 16C 125W 2.0GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A00QAU 4x Platinum 8153 16C 125W 2.0GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A003AU 8x Platinum 8160 24C 150W 2.1GHz 2 8x 32GB 2x RAID 930-16i 24x 2.5" Open Open 17 (0,0,2,1) 4x 1600W HS
7X12 A00EAU 8x Platinum 8160 24C 150W 2.1GHz 2 8x 32GB 2x RAID 930-16i 24x 2.5" Open Open 17 (0,0,2,1) 4x 1600W HS
7X12 A00NAU 8x Platinum 8160 24C 150W 2.1GHz 2 8x 32GB 2x RAID 930-16i 24x 2.5" Open Open 17 (0,0,2,1) 4x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for South East Asian countries (ASEAN)

Table 8. Models for South East Asian countries (ASEAN)
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A015SG 2x Platinum 8153 16C 125W 2.0GHz 1 4x 32GB 1x RAID 930-16i 12x 2.5" Open 4x10Gb RJ45 5 (0,0,0,0) 2x 1600W HS
7X12 A016SG 2x Platinum 8158 12C 150W 3.0GHz 1 4x 32GB 1x RAID 930-16i 12x 2.5" Open 4x10Gb RJ45 5 (0,0,0,0) 2x 1600W HS
7X12 A014SG 2x Platinum 8160 24C 150W 2.1GHz 1 4x 32GB 1x RAID 930-16i 12x 2.5" Open 4x10Gb RJ45 5 (0,0,0,0) 2x 1600W HS
7X12 A01BSG 2x Platinum 8164 26C 150W 2.0GHz 1 4x 32GB 1x RAID 930-16i 12x 2.5" Open 4x10Gb RJ45 5 (0,0,0,0) 2x 1600W HS
7X12 A01CSG 2x Platinum 8176 28C 165W 2.1GHz 1 4x 32GB 1x RAID 930-16i 12x 2.5" Open 4x10Gb RJ45 5 (0,0,0,0) 2x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for Brazil

Table 9. Models for Brazil
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A01WBR 4x Gold 5120 14C 105W 2.2GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A01TBR 2x Gold 6130 16C 125W 2.1GHz 1 2x 32GB 1x RAID 930-8i 8x 2.5" Open Open 5 (0,0,0,0) 2x 1100W HS
7X12 A01VBR 4x Platinum 8153 16C 125W 2.0GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A01UBR 8x Platinum 8160 24C 150W 2.1GHz 2 8x 32GB 2x RAID 930-16i 24x 2.5" Open Open 17 (0,0,2,1) 4x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for EMEA countries

Table 10. Models for EMEA countries
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A019EA 4x Gold 5120 14C 105W 2.2GHz 1 4x 32GB 1x RAID 930-16i 12x 2.5" (6x AnyBay) Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A01AEA 2x Gold 6130 16C 125W 2.1GHz 1 2x 32GB 1x RAID 930-8i 8x 2.5" Open Open 5 (0,0,0,0) 2x 1600W HS
7X12 A018EA 4x Platinum 8153 16C 125W 2.0GHz 1 4x 32GB 1x RAID 930-16i 12x 2.5" (6x AnyBay) Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A017EA 8x Platinum 8160 24C 150W 2.1GHz 2 8x 32GB 2x RAID 930-16i 24x 2.5" (12x AnyBay) Open Open 17 (0,0,2,1) 4x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for Hong Kong, Taiwan, Korea (HTK)

Table 11. Models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A01KCN 2x Gold 6130 16C 125W 2.1GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01RCN 2x Gold 6140 18C 140W 2.3GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01PCN 2x Gold 6142 16C 150W 2.6GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01NCN 2x Gold 6148 20C 150W 2.4GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01LCN 2x Gold 6152 22C 140W 2.1GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01JCN 2x Platinum 8153 16C 125W 2.0GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01HCN 2x Platinum 8156 4C 105W 3.6GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01QCN 2x Platinum 8160 24C 150W 2.1GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01FCN 2x Platinum 8170 26C 165W 2.1GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS
7X12 A01ECN 2x Platinum 8180 28C 205W 2.5GHz 1 2x 16GB 2Rx8 1x RAID 930-16i 12x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for India

Table 12. Models for India
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A00VSG 2x Gold 6126 12C 125W 2.6GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A002SG 2x Gold 6132 14C 140W 2.6GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A008SG 2x Gold 6140 18C 140W 2.3GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A004SG 2x Gold 6142 16C 150W 2.6GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A00ASG 2x Gold 6148 20C 150W 2.4GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A009SG 2x Gold 6150 18C 165W 2.7GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A005SG 2x Gold 6152 22C 140W 2.1GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A00PSG 2x Platinum 8158 12C 150W 3.0GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A011SG 2x Platinum 8164 26C 150W 2.0GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A00YSG 2x Platinum 8180 28C 205W 2.5GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A00JSG 2x Gold 6134M 8C 130W 3.2GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A00KSG 2x Gold 6134M 8C 130W 3.2GHz 1 2x 32GB 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A006SG 2x Gold 6140M 18C 140W 2.3GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A010SG 2x Gold 6142M 16C 150W 2.6GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A001SG 2x Gold 6142M 16C 150W 2.6GHz 1 2x 32GB 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A00DSG 2x Platinum 8160M 24C 150W 2.1GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS
7X12 A00ZSG 2x Platinum 8160M 24C 150W 2.1GHz 1 2x 32GB 1x RAID 930-16i 4x 2.5" Open 4x1Gb 5 (0,0,0,0) 2x 1100W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for Japan

Table 13. Models for Japan
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A00MJP 2x Gold 6128 6C 115W 3.4GHz 1 4x 16GB 1Rx4 1x RAID 930-16i 8x 2.5" (4x AnyBay) Open 4x10Gb RJ45 7 (0,0,0,1) 4x 1100W HS
7X12 A013JP 2x Gold 6154 18C 200W 3.0GHz 1 2x 16GB 1Rx4 1x RAID 930-16i 8x 2.5" (2x AnyBay) Open 4x10Gb RJ45 7 (0,0,0,1) 2x 1600W HS
7X12 A012JP 4x Platinum 8180 28C 205W 2.5GHz 1 4x 16GB 1Rx4 1x RAID 930-16i 8x 2.5" (4x AnyBay) Open 4x10Gb RJ45 7 (0,0,0,1) 4x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for Latin American countries (except Brazil)

Table 14. Models for Latin American countries (except Brazil)
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A024LA 4x Platinum 8153 16C 125W 2.0GHz 2 24x 16GB 2Rx8 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS
7X12 A022LA 4x Platinum 8164 26C 150W 2.0GHz 2 24x 16GB 2Rx8 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS
7X12 A020LA 4x Platinum 8170 26C 165W 2.1GHz 2 24x 16GB 2Rx8 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS
7X12 A01YLA 4x Platinum 8176 28C 165W 2.1GHz 2 24x 16GB 2Rx8 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS
7X12 A01ZLA 4x Platinum 8176 28C 165W 2.1GHz 2 24x 32GB 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS
7X12 A025LA 4x Platinum 8180 28C 205W 2.5GHz 2 24x 16GB 2Rx8 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS
7X12 A023LA 4x Platinum 8180 28C 205W 2.5GHz 2 24x 32GB 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS
7X12 A021LA 8x Platinum 8180M 28C 205W 2.5GHz 2 48x 32GB 2x RAID 930-16i 24x 2.5" (4x AnyBay) Open 4x10Gb SFP+ 11 (0,0,1,0) 4x 1600W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser

Models for USA and Canada

Table 15. Models for USA and Canada
Model Intel Xeon
processors†
Compute
trays
Memory RAID Drive bays Drives Ethernet
LOM
Slots* Power
supplies
7X12 A01GNA 4x Gold 5120 14C 105W 2.2GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" (4x AnyBay) Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A01DNA 2x Gold 6130 16C 125W 2.1GHz 1 2x 32GB 1x RAID 930-8i 8x 2.5" (2x AnyBay) Open Open 5 (0,0,0,0) 2x 1100W HS
7X12 A01MNA 4x Platinum 8153 16C 125W 2.0GHz 1 4x 32GB 1x RAID 930-8i 8x 2.5" (4x AnyBay) Open Open 11 (2,0,0,1) 2x 1600W HS
7X12 A01SNA 8x Platinum 8160 24C 150W 2.1GHz 2 8x 32GB 2x RAID 930-16i 24x 2.5" (12x AnyBay) Open Open 17 (0,0,2,1) 4x 1600W HS
7X12 A027NA‡ 4x Platinum 8180 28C 205W 2.5GHz 1 48x 32GB 1x RAID 530-8i 8x 2.5" See note‡ 2x1Gb 15 (0,2,0,1) 4x 1100W HS

† Processor detail: Quantity, model, core count, TDP, core frequency
* Values in brackets are numbers of riser cards: (A,B,C,D) where A=2x16 Riser, B=4x8 Riser, C=5x16+ML2 Riser, D=2x8 Riser
‡ Model 7X12A027NA is a 90TB Microsoft Data Warehouse Fast Track (DWFT) offering as described in this solution brief and is comprised of the following storage components:

  • 8x HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter (for data and tempdb)
  • 2x 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD, 7N47A00112 (for OS)
  • 6x 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD, 7N47A00118 (for logging)
  • Note: Microsoft Windows and SQL Server licenses are not included

SAP HANA configurations

The Lenovo SR950 solutions for SAP HANA provide optimal solutions for SAP BW/4HANA and SAP S/4HANA applications.

The following table lists the configurations available for SAP HANA (machine type 7X13).

System upgrades to 8 sockets: SAP HANA configurations described here can be upgraded to 4 or 8 sockets as described in the Server configuration upgrades section. Refer to the Configuration 1 and Configuration 2 rows in the table.

Table 16. SAP HANA configurations
Memory Config
identifier
Config Intel Xeon
Processor
Memory
configuration
Drives RAID Storage
capacity
Network
All-flash configurations - 2 socket - standalone server
192 GB 2SKL192
SSDS
Single node 2x 8176 192 GB
(12x 16 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
384 GB 2SKL384
SSDS
Single node 2x 8176 384 GB
(24x 16 GB or
12x 32 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
576 GB 2SKL576
SSDS
Single
node
2x 8176 576 GB
(12x 16GB +
12x 32GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
768 GB 2SKL768
SSDS
Single node 2x 8176 768 GB
(24x 32 GB or
12x 64 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
1,536 GB 2SKL1536
SSDS
Single node 2x 8176 1,536 GB
(24x 64 GB or
12x 128 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
3,072 GB* 2SKL3072
SSDS
Single node 2x 8176M 3,072 GB
(24x 128 GB)
2x 400GB SSD
5x 3.84TB SSD
1x 930-16i 15.3 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
All-flash configurations - 4 socket - standalone
384 GB 4SKL384
SSDS
Single node 4x 8176 384 GB
(24x 16 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
768 GB 4SKL768
SSDS
Single node 4x 8176 768 GB
(48x 16 GB or
24x 32 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
1,152 GB 4SKL1152
SSDS
Single node 4x 8176 1152 GB
(24x 16GB +
24x 32GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
1,536 GB 4SKL1536
SSDS
Single node 4x 8176 1,536 GB
(48x 32 GB or
24x 64 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
3,072 GB 4SKL3072
SSDS
Single node 4x 8176 3,072 GB
(48x 64 GB or
24x 128 GB)
2x 400GB SSD
5x 3.84TB SSD
1x 930-16i 15.3 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
6,144 GB* 4SKL6144
SSDS
Single node 4x 8176M 6,144 GB
(48x 128 GB)
2x 400GB SSD
9x 3.84TB SSD
1x 930-16i 30.7 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
All-flash configurations - 8 socket - standalone
768 GB 8SKL768
SSDS
Single node 8x 8176 768 GB
(48x 16 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
1,536 GB 8SKL1536
SSDS
Single node 8x 8176 1,536 GB
(96x 16 GB or
48x 32 GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
2,304GB 8SKL2304
SSDS
Single node 8x 8176 2,304 G
(48x 16GB +
48x 32GB)
2x 400GB SSD
3x 3.84TB SSD
1x 930-16i 7.6 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
3,072 GB 8SKL3072
SSDS
Single node 8x 8176 3,072 GB
(96x 32 GB or
48x 64 GB)
2x 400GB SSD
5x 3.84TB SSD
1x 930-16i 15.3 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
6,144 GB 8SKL6144
SSDS
Single node 8x 8176 6,144 GB
(96x 64 GB or
48x 128 GB)
2x 400GB SSD
9x 3.84TB SSD
1x 930-16i 30.7 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
12,288 GB* 8SKL12288
SSDS
Single node 8x 8176M 12,288 GB
(96x 128 GB)
2x 400GB SSD
18x 3.84TB SSD or
9x 7.68TB SSD
2x 930-16i† 61.4 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
All-flash configurations - 4 socket - scaleout
1,536 GB 4SKL1536
SSDG
Scaleout to
94 nodes
4x 8176 1,536 GB
(48x 32 GB or
24x 64 GB)
2x 400GB SSD
5x 3.84TB SSD
1x 930-16i 15.3 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
3,072 GB 4SKL3072
SSDG
Scaleout to
94 nodes
4x 8176 3,072 GB
(48x 64 GB or
24x 128 GB)
2x 400GB SSD
9x 3.84TB SSD
1x 930-16i 30.7 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
All-flash configurations - 8 socket - scaleout
3,072 GB 8SKL3072
SSDG
Scaleout to
94 nodes
8x 8176 3,072 GB
(96x 32 GB or
48x 64 GB)
2x 400GB SSD
9x 3.84TB SSD
1x 930-16i 30.7 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
6,144 GB** 8SKL6144
SSDG
Scaleout to
94 nodes
8x 8176 6,144 GB
(96x 64 GB or
48x 128 GB)
2x 400GB SSD
18x 3.84TB SSD or
9x 7.68TB SSD
2x 930-16i† 61.4 TB
RAID-5
data/log
4x 10GbE
4x 1GigE
12,288 GB‡ 8SKL12288
SSDG
Scaleout to
4+1 node
8x 8176M 12,288 GB
(96x 128 GB)
2x 400GB SSD
18x 7.68TB SSD
2x 930-16i 122.8 TB
RAID-5
data/log
4x 10GbE
4x 1GigE

* For S/4HANA and Suite on HANA only (not for Datamart, BWoH and BW/4)
** Up to 4 nodes for S/4HANA (scale-out up to 94 nodes for Datamart, BWoH and BW/4H only)
‡ For S/4HANA only
† if 9x 7.68TB drives are used, then use 1x 930-16i RAID adapter

Each of these HANA configurations include the following components

  • Processors:
    • Each configuration listed in the table uses either the Platinum 8176 or 8176M processors, depending on the amount of memory installed. The Platinum 8180 and 8180M can also be used if greater performance is desired.
    • An M-suffix processor is required for 8-socket configurations with 12TB of memory, for 4-socket configurations with 6TB of memory, or for 2-socket configurations with 3TB of memory.
  • Networking:
    • Two or more Mellanox ConnectX-4 Lx 2x 25GbE Adapters with 10 GbE transceivers (SFP+ SR Transceiver, 46C3447)
    • One or more ThinkSystem Intel I350-T4 ML2 1Gb 4-Port RJ45 Ethernet Adapters
  • Storage
    • ThinkSystem 2.5" 400GB Mainstream SAS 12Gb Hot Swap SSDs
    • ThinkSystem 2.5" 3.84TB Capacity SAS 12Gb Hot Swap SSDs
  • RAID Adapter:
    • One or two ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
    • Optional RAID 930-8e 4GB Flash PCIe 12Gb Adapters for external storage connectivity
  • Lenovo solution for SAP HANA media

Note: The operating system software is not included with the SAP HANA models. Operating system selection must be a separate line item included in order: SLES for SAP with standard or priority support. The SAP HANA Software is included, but the license is sold separately by SAP or an SAP business partner. VMware Enterprise Plus license sold separately. IBM Spectrum Scale (GPFS) is available from Lenovo separately.

For more information about the standard features of the server, see the Standard specifications section.

SAP HANA models

In addition to the configurations listed in the SAP HANA configurations section, Lenovo also offers predefined models available to customers in certain countries. The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Common to all SAP HANA models:

  • All models have the five onboard slots but no riser cards
  • Network adapters as listed in the tables, however no LOM adapter is included
  • Each Mellanox ConnectX-4 Lx 2x25G SFP28 PCIe adapter includes two 10Gb SFP+ SR transceivers
  • All models include a rail kit
  • All models come standard with four 1600 W power supplies
  • All models include 2.8m, 10A/100-250V, C13 to C14 Jumper Cords (one per installed power supply)

The models also include the SAP HANA Software Stack for ThinkSystem which includes following software:

  • Lenovo Automated SW Solution Installer
  • SAP HANA Platform Edition 2.0 (license must be purchased separately)
  • SAP IT Operations Analytics 2.0 (license must be purchased separately)

System upgrades to 8 sockets: SAP HANA configurations described here can be upgraded to 4 or 8 sockets as described in the Server configuration upgrades section. Refer to the Configuration 1 and Configuration 2 rows in the table.

Tip: The models in the tables below are sorted by total memory capacity.

SAP HANA models for Australia and New Zealand

Table 17. SAP HANA models for Australia and New Zealand
Model Intel Xeon CPUs† (Compute trays) Memory RAID Drive bays Drives Ethernet adapters
7X13 A009AU 2x Platinum 8176 28C 165W 2.1GHz (1) 192 GB
12x 16GB 2Rx8
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00CAU 2x Platinum 8176 28C 165W 2.1GHz (1) 384 GB
12x 32GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A003AU 2x Platinum 8176 28C 165W 2.1GHz (1) 768 GB
12x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A008AU 4x Platinum 8176 28C 165W 2.1GHz (1) 1.5 TB
24x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00BAU 2x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A005AU 4x Platinum 8176 28C 165W 2.1GHz (1) 3 TB
48x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A006AU 4x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A004AU 4x Platinum 8176M 28C 165W 2.1GHz (1) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A002AU 8x Platinum 8176 28C 165W 2.1GHz (2) 6 TB
96x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00AAU 8x Platinum 8176M 28C 165W 2.1GHz (2) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A007AU 8x Platinum 8176M 28C 165W 2.1GHz (2) 12 TB
96x 128GB
2x RAID 930-16i 24x 2.5" 2x 2.5" 400GB PM1635a
18x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2

† Processor detail: Quantity, model, core count, TDP, core frequency

SAP HANA models for EMEA countries

Table 18. SAP HANA models for EMEA countries
Model Intel Xeon CPUs† (Compute trays) Memory RAID Drive bays Drives Ethernet adapters
7X13 A009EA 2x Platinum 8176 28C 165W 2.1GHz (1) 192 GB
12x 16GB 2Rx8
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00CEA 2x Platinum 8176 28C 165W 2.1GHz (1) 384 GB
12x 32GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A003EA 2x Platinum 8176 28C 165W 2.1GHz (1) 768 GB
12x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A008EA 4x Platinum 8176 28C 165W 2.1GHz (1) 1.5 TB
24x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A005EA 4x Platinum 8176 28C 165W 2.1GHz (1) 3 TB
48x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A006EA 4x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00HEA 2x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A002EA 8x Platinum 8176 28C 165W 2.1GHz (2) 6 TB
96x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A004EA 4x Platinum 8176M 28C 165W 2.1GHz (1) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00AEA 8x Platinum 8176M 28C 165W 2.1GHz (2) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00QEA 8x Platinum 8176M 28C 165W 2.1GHz (2) 12 TB
96x 128GB
2x RAID 930-16i 24x 2.5" 2x 2.5" 400GB PM1635a
18x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2

† Processor detail: Quantity, model, core count, TDP, core frequency

SAP HANA models for Latin American countries (except Brazil)

Table 19. SAP HANA models for Latin American countries (except Brazil)
Model Intel Xeon CPUs† (Compute trays) Memory RAID Drive bays Drives Ethernet adapters
7X13 A00ELA 2x Platinum 8176 28C 165W 2.1GHz (1) 192 GB
12x 16GB 2Rx8
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00FLA 2x Platinum 8176 28C 165W 2.1GHz (1) 384 GB
12x 32GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00GLA 2x Platinum 8176 28C 165W 2.1GHz (1) 768 GB
12x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00JLA 4x Platinum 8176 28C 165W 2.1GHz (1) 1.5 TB
24x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00HLA 2x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00KLA 4x Platinum 8176 28C 165W 2.1GHz (1) 3 TB
48x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00LLA 4x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00MLA 4x Platinum 8176M 28C 165W 2.1GHz (1) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00NLA 8x Platinum 8176 28C 165W 2.1GHz (2) 6 TB
96x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00PLA 8x Platinum 8176M 28C 165W 2.1GHz (2) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00QLA 8x Platinum 8176M 28C 165W 2.1GHz (2) 12 TB
96x 128GB
2x RAID 930-16i 24x 2.5" 2x 2.5" 400GB PM1635a
18x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2

† Processor detail: Quantity, model, core count, TDP, core frequency

SAP HANA models for Hong Kong, Taiwan, Korea (HTK)

Table 20. SAP HANA models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon CPUs† (Compute trays) Memory RAID Drive bays Drives Ethernet adapters
7X13 A009CN 2x Platinum 8176 28C 165W 2.1GHz (1) 192 GB
12x 16GB 2Rx8
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00CCN 2x Platinum 8176 28C 165W 2.1GHz (1) 384 GB
12x 32GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A003CN 2x Platinum 8176 28C 165W 2.1GHz (1) 768 GB
12x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00DCN 2x Platinum 8176M 28C 165W 2.1GHz (1) 1.5 TB
12x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A008CN 4x Platinum 8176 28C 165W 2.1GHz (1) 1.5 TB
24x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00BCN 2x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A005CN 4x Platinum 8176 28C 165W 2.1GHz (1) 3 TB
48x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A006CN 4x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A004CN 4x Platinum 8176M 28C 165W 2.1GHz (1) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A002CN 8x Platinum 8176 28C 165W 2.1GHz (2) 6 TB
96x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00ACN 8x Platinum 8176M 28C 165W 2.1GHz (2) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A007CN 8x Platinum 8176M 28C 165W 2.1GHz (2) 12 TB
96x 128GB
2x RAID 930-16i 24x 2.5" 2x 2.5" 400GB PM1635a
18x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2

† Processor detail: Quantity, model, core count, TDP, core frequency

SAP HANA models for Japan

Table 21. SAP HANA models for Japan
Model Intel Xeon CPUs† (Compute trays) Memory RAID Drive bays Drives Ethernet adapters
7X13 A009JP 2x Platinum 8176 28C 165W 2.1GHz (1) 192 GB
12x 16GB 2Rx8
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00CJP 2x Platinum 8176 28C 165W 2.1GHz (1) 384 GB
12x 32GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A003JP 2x Platinum 8176 28C 165W 2.1GHz (1) 768 GB
12x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A008JP 4x Platinum 8176 28C 165W 2.1GHz (1) 1.5 TB
24x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00BJP 2x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A005JP 4x Platinum 8176 28C 165W 2.1GHz (1) 3 TB
48x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A006JP 4x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A004JP 4x Platinum 8176M 28C 165W 2.1GHz (1) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A002JP 8x Platinum 8176 28C 165W 2.1GHz (2) 6 TB
96x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00AJP 8x Platinum 8176M 28C 165W 2.1GHz (2) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A007JP 8x Platinum 8176M 28C 165W 2.1GHz (2) 12 TB
96x 128GB
2x RAID 930-16i 24x 2.5" 2x 2.5" 400GB PM1635a
18x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2

† Processor detail: Quantity, model, core count, TDP, core frequency

SAP HANA models for USA and Canada

Table 22. SAP HANA models for USA and Canada
Model Intel Xeon CPUs† (Compute trays) Memory RAID Drive bays Drives Ethernet adapters
7X13 A009NA 2x Platinum 8176 28C 165W 2.1GHz (1) 192 GB
12x 16GB 2Rx8
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00CNA 2x Platinum 8176 28C 165W 2.1GHz (1) 384 GB
12x 32GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A003NA 2x Platinum 8176 28C 165W 2.1GHz (1) 768 GB
12x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A008NA 4x Platinum 8176 28C 165W 2.1GHz (1) 1.5 TB
24x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
3x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00BNA 2x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A005NA 4x Platinum 8176 28C 165W 2.1GHz (1) 3 TB
48x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A006NA 4x Platinum 8176M 28C 165W 2.1GHz (1) 3 TB
24x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
5x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A004NA 4x Platinum 8176M 28C 165W 2.1GHz (1) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A002NA 8x Platinum 8176 28C 165W 2.1GHz (2) 6 TB
96x 64GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A00ANA 8x Platinum 8176M 28C 165W 2.1GHz (2) 6 TB
48x 128GB
1x RAID 930-16i 12x 2.5" 2x 2.5" 400GB PM1635a
9x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2
7X13 A007NA 8x Platinum 8176M 28C 165W 2.1GHz (2) 12 TB
96x 128GB
2x RAID 930-16i 24x 2.5" 2x 2.5" 400GB PM1635a
18x 2.5" 3.84TB PM1633a
2x CX-4 Lx 2x25GbE
1x 4x1GbE I350 ML2

† Processor detail: Quantity, model, core count, TDP, core frequency

Processor options

The SR950 supports the Gold and Platinum level processors in the Intel Xeon Processor Scalable Family, including the "top bin" highest performing 205 W processors available from Intel.

The server supports up to four or eight processors, depending on the configuration selected, however processors are all installed within the 4U rack enclosure:

  • For configurations that support up to eight processors, the server supports 2, 4, 6 or 8 processors
  • For configurations of up to four processors (lower cost configuration, no upgrade path to eight processors), the server supports 2, 3 or 4 processors

As described in the Components and connectors section, processors and memory are located on compute system boards - two processors per board. Two system boards are installed in a compute tray, and there are two compute trays in the server. 

For configurations with only one compute tray, you can upgrade to add a second compute tray. You can also add additional system boards as needed. The ordering information for these upgrades is listed in the following table.

Table 23. Compute tray and system board upgrades
Part number Feature code Description
7XG7A03955 AUN0 ThinkSystem SR950 2-CPU, 24 DIMM Compute System Board
7XG7A03956 Various ThinkSystem SR950 Upper Compute Tray Kit

The Compute System Board option, 7XG7A03955, includes the following components:

  • One compute system board, without processors or memory

The Upper Compute Tray Kit, 7XG7A03956, includes the following components:

  • 1x compute tray with 12 drive bays and 1 slot for storage adapter
  • 1x compute system board
  • 3x 4-bay drive bay fillers

Note: The Upper Compute Tray Kit does not include drive backplanes

The table below lists the supported processors. The table indicates which processors support 8-socket configurations and whether the processors support memory capacities greater than 768 GB per processor.

All processors listed support:

  • Hyper-Threading Technology
  • Turbo Boost Technology 2.0

The table also lists the number of UltraPath Interconnect (UPI) ports each processor has. UPI ports are used to connect processors together for high-speed communications.

  • When a processor has 3 UPI ports, it can be used in a 4-socket mesh configuration where all processors are directly connected to every other processor. 5100 Series processors do not support mesh topology, since they only have 2 UPI ports.
  • When a processor has only 2 UPI ports, it can only be used in a 4-socket ring configuration where all processors are connected to the 2 adjacent processors and the fourth processor is only connected indirectly via another processor.

The mesh and ring topologies are shown in the following figure.

Mesh and ring processor topologies
Figure 10. Mesh and ring processor topologies

Table 24. Processor options
Part
number
Feature
code
Intel Xeon processor Suitable for
8-socket
Memory
speed
Supports
>768 GB
per CPU
L3 cache UPI
links
AVX-
512
units
4XG7A08857 AX8M Gold 5115 10C 85W 2.4GHz No 2400 MHz No 13.75 MB 2 1
4XG7A09097 B20S Gold 5117 14C 105W 2.0GHz No 2400 MHz No 19.25 MB 2 1
4XG7A08845 AX7D Gold 5118 12C 105W 2.3GHz No 2400 MHz No 16.5 MB 2 1
4XG7A08864 AX7F Gold 5119T 14C 85W 1.9GHz No 2400 MHz No 19.25 MB 2 1
4XG7A08832 AX7C Gold 5120 14C 105W 2.2GHz No 2400 MHz No 19.25 MB 2 1
4XG7A08831 AX7E Gold 5120T 14C 105W 2.2GHz No 2400 MHz No 19.25 MB 2 1
4XG7A08849 AX70 Gold 5122 4C 105W 3.6GHz No 2666 MHz* No 16.5 MB** 2 2*
4XG7A08835 AWEX Gold 6126 12C 125W 2.6GHz No 2666 MHz No 19.25 MB** 3 2
4XG7A08853 AX73 Gold 6126T 12C 125W 2.6GHz No 2666 MHz No 19.25 MB** 3 2
4XG7A08846 AX6Z Gold 6128 6C 115W 3.4GHz No 2666 MHz No 19.25 MB** 3 2
4XG7A08833 AX6D Gold 6130 16C 125W 2.1GHz No 2666 MHz No 22 MB 3 2
4XG7A08851 AX72 Gold 6130T 16C 125W 2.1GHz No 2666 MHz No 22 MB 3 2
4XG7A08838 AX6U Gold 6132 14C 140W 2.6GHz No 2666 MHz No 19.25 MB 3 2
4XG7A08847 AX6Y Gold 6134 8C 130W 3.2GHz No 2666 MHz No 24.75 MB** 3 2
4XG7A08863 AX7A Gold 6134M 8C 130W 3.2GHz No 2666 MHz Yes 24.75 MB** 3 2
4XG7A08848 AX6W Gold 6136 12C 150W 3.0GHz No 2666 MHz No 24.75 MB** 3 2
4XG7A08834 AX6Q Gold 6138 20C 125W 2.0GHz No 2666 MHz No 27.5 MB 3 2
4XG7A08852 AX71 Gold 6138T 20C 125W 2.0GHz No 2666 MHz No 27.5 MB 3 2
4XG7A08836 AX6R Gold 6140 18C 140W 2.3GHz No 2666 MHz No 24.75 MB 3 2
4XG7A08858 AX79 Gold 6140M 18C 140W 2.3GHz No 2666 MHz Yes 24.75 MB 3 2
4XG7A08839 AX6E Gold 6142 16C 150W 2.6GHz No 2666 MHz No 22 MB 3 2
4XG7A08859 AX78 Gold 6142M 16C 150W 2.6GHz No 2666 MHz Yes 22 MB 3 2
7XG7A05003 AX6X Gold 6144 8C 150W 3.5GHz No 2666 MHz No 24.75 MB** 3 2
7XG7A05004 AX6V Gold 6146 12C 165W 3.2GHz No 2666 MHz No 24.75 MB** 3 2
4XG7A08840 AWEW Gold 6148 20C 150W 2.4GHz No 2666 MHz No 27.5 MB 3 2
7XG7A05005 AX6T Gold 6150 18C 165W 2.7GHz No 2666 MHz No 24.75 MB 3 2
4XG7A08837 AX6P Gold 6152 22C 140W 2.1GHz No 2666 MHz No 30.25 MB 3 2
7XG7A03957 AX6S Gold 6154 18C 200W 3.0GHz No 2666 MHz No 24.75 MB 3 2
4XG7A08854 AX6L Platinum 8153 16C 125W 2.0GHz Yes 2666 MHz No 22 MB 3 2
4XG7A08850 AWEV Platinum 8156 4C 105W 3.6GHz Yes 2666 MHz No 16.5 MB** 3 2
4XG7A08855 AX7B Platinum 8158 12C 150W 3.0GHz Yes 2666 MHz No 24.75 MB** 3 2
4XG7A08841 AWGJ Platinum 8160 24C 150W 2.1GHz Yes 2666 MHz No 33 MB 3 2
4XG7A08860 AX77 Platinum 8160M 24C 150W 2.1GHz Yes 2666 MHz Yes 33 MB 3 2
4XG7A08856 AX6N Platinum 8160T 24C 150W 2.1GHz Yes 2666 MHz No 33 MB 3 2
4XG7A08842 AX6K Platinum 8164 26C 150W 2.0GHz Yes 2666 MHz No 35.75 MB 3 2
7XG7A03958 AX6M Platinum 8168 24C 205W 2.7GHz Yes 2666 MHz No 33 MB 3 2
4XG7A08843 AX6J Platinum 8170 26C 165W 2.1GHz Yes 2666 MHz No 35.75 MB 3 2
4XG7A08862 AX76 Platinum 8170M 26C 165W 2.1GHz Yes 2666 MHz Yes 35.75 MB 3 2
4XG7A08844 AX6H Platinum 8176 28C 165W 2.1GHz Yes 2666 MHz No 38.5 MB 3 2
4XG7A08861 AX75 Platinum 8176M 28C 165W 2.1GHz Yes 2666 MHz Yes 38.5 MB 3 2
7XG7A03959 AX6G Platinum 8180 28C 205W 2.5GHz Yes 2666 MHz No 38.5 MB 3 2
7XG7A03960 AX74 Platinum 8180M 28C 205W 2.5GHz Yes 2666 MHz Yes 38.5 MB 3 2

* All Gold 5000-level processors, except the 5122, support 2400 MHz memory speeds and have one AVX-512 512-bit FMA units. The 5122 processor supports 2666 MHz and has two FMA units
** L3 cache is 1.375 MB per core except with the processors indicated with **

Memory options

The SR950 uses Lenovo TruDDR4 memory operating at up to 2666 MHz. The server supports 12 DIMMs per processor, which corresponds to 48 DIMMs with four processors installed and 96 DIMMs when eight processors are installed. Each processor has six memory channels with two DIMMs per channel. With 128 GB 3DS RDIMMs installed, an 8-socket server supports a total of 12 TB of system memory.

As described in the Components and connectors section, the memory is installed on compute system boards and there are two system boards per compute tray and one or two compute trays per server, depending on the configuration.

All DIMMs operate at a speed of 2666 MHz, both at 1 DIMM per channel and 2 DIMMs per channel. However, if the processor selected has a lower memory bus speed (eg 2400 MHz), then all DIMMs will operate at that lower speed.

The following table lists the memory options that are available for SR950.

Lenovo TruDDR4 memory uses the highest quality components that are sourced from Tier 1 DRAM suppliers and only memory that meets the strict requirements of Lenovo is selected. It is compatibility tested and tuned to maximize performance and reliability. From a service and support standpoint, Lenovo TruDDR4 memory automatically assumes the system warranty, and Lenovo provides service and support worldwide.

Table 25. Memory options
Part
number
Feature
code
Description Maximum
supported
RDIMMs
7X77A01302 AUNB ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM 96 (12 per processor)
7X77A01303 AUNC ThinkSystem 16GB TruDDR4 2666 MHz (2Rx8 1.2V) RDIMM 96 (12 per processor)
7X77A01304 AUND ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM 96 (12 per processor)
LRDIMMs
7X77A01305 AUNE ThinkSystem 64GB TruDDR4 2666 MHz (4Rx4 1.2V) LRDIMM 96 (12 per processor)
3DS RDIMMs
4ZC7A08716 AUW5 ThinkSystem 64GB TruDDR4 2666MHz (4Rx4, 1.2V) 3DS RDIMM 96 (12 per processor)
7X77A01307 AUNF ThinkSystem 128GB TruDDR4 2666 MHz (8Rx4 1.2V) 3DS RDIMM 96 (12 per processor)

The following rules apply when selecting the memory configuration:

  • The server supports RDIMMs, LRDIMMs and 3DS RDIMMs. UDIMMs are not supported.
  • Mixing RDIMMs and LRDIMMs is not supported.
  • Mixing 3DS RDIMMs with either RDIMMs or LRDIMMs is not supported.
  • Mixing x4 and x8 DIMMs is supported.

For best performance, consider the following:

  • Populate memory DIMMs in quantities of 6 or 12 per processor, so that all memory channels are used.
  • When mixing 16 GB and 32 GB DIMMs in the same configuration, use 16GB 2Rx8 DIMMs instead of 16 GB 1Rx4 DIMMs for better performance.
  • Populate memory channels so they all have the same total memory capacity
  • Ensure all memory controllers on a processor socket have the same DIMM configuration.
  • All processor sockets on the same physical server should have the same DIMM configuration.

The following memory protection technologies are supported:

  • ECC
  • SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
  • ADDDC (for x4-based memory DIMMs)
  • Memory mirroring
  • Memory rank sparing

If memory channel mirroring is used, then DIMMs must be installed in pairs or sets of three (minimum of one pair or set of three per processor), and all DIMMs in the pair or set of three must be identical in type and size. 50% of the installed capacity is available to the operating system.

If memory rank sparing is used, then a minimum of two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The largest rank in the channel will be automatically selected as the spare rank. The amount of memory available to the operating system depends on the number, capacity and rank counts of the DIMMs installed.

Internal storage

The SR950 offers up to 24x 2.5-inch drive bays, depending on the server configuration selected (as described in Server configurations). The server also supports either one or two M.2 drives, installed in an M.2 adapter.

In this section:

Backplanes and drive bays

Drives are all located at the front of the server, 12 drives at the front of the upper tray and 12 at the front of the lower tray. Drives are connected to 4-drive backplanes in a 2-by-2 configuration, as shown in the following figure. All drive bays are 2.5-inch form factor.

Location of backplanes
Figure 11. Location of backplanes

There are two different backplanes available for the SR950:

  • SAS/SATA backplane: Supports 4 SAS or SATA drives
  • AnyBay backplane:
    • Top two drives support SAS, SATA, or NVMe interface drives (Lenovo AnyBay)
    • Bottom two drive bays support SAS or SATA drives only

Regular 2.5-inch SAS/SATA drive bays support only SAS or SATA drives; however, the Lenovo AnyBay drive bay design allows a choice of SATA, SAS, or U.2 (NVMe) PCIe drives. This design enables the flexibility to configure some of the bays with high-performance PCIe SSDs while still using the other bays for high-capacity HDDs, which is an ideal solution for storage-tiering.

Table 26. Drive backplanes
Part
number
Feature
code
Description Maximum
supported
7XB7A03966 AUN6 ThinkSystem 2.5" SAS/SATA 2x2 Bay Backplane Kit 6
7XB7A03965 AUN5 ThinkSystem 2.5" SAS/SATA/NVMe 2x2 Bay Backplane Kit 6

If the server is configured with all AnyBay backplanes, then the server supports up to 12 NVMe drives, depending on the server configuration. The NVMe-capable drive bays are the even-numbered bays as shown in the following figure.

SR950 Drive bay numbering
Figure 12. Drive bay numbering

The quantity and location of the AnyBay drive bays depends on the configuration, as listed in the following table.

See the Server configurations section for details about the five server configurations.

Table 27. Drive bays and NVMe support for each SR950 configuration
Configuration Maximum storage Location of NVMe drive bays
(see previous figure for bay numbering)
Configuration 1. Four-Socket Performance
2 processors installed 12 drives (2 NVMe) Bays 8 and 10
3 processors installed 12 drives (4 NVMe) Bays 4, 6, 8, 10
4 processors installed 12 drives (6 NVMe) Bays 0, 2, 4, 6, 8, 10
Configuration 2. Four-Socket Performance/ Storage Rich
2 processors installed 24 drives (4 NVMe) Bays 8, 10 and 20, 22
3 processors installed 24 drives (8 NVMe) Bays 4, 6, 8, 10, and 16, 18, 20, 22
4 processors installed 24 drives (12 NVMe) Bays 0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22
Configuration 3. Four-Socket Upgradable
2 processors installed 12 drives (2 NVMe) Bays 8 and 10
4 processors installed 12 drives (6 NVMe) Bays 0, 2, 4, 6, 8, 10
Configuration 4. Four-Socket Upgradable / Storage Rich
4 processors installed 24 drives (4 NVMe) Bays 8, 10 and 20, 22
Configuration 5. Eight-Socket Storage Rich
6 processors installed 24 drives (8 NVMe) Bays 0, 2, 4, 6, 8, 10 and 12, 14
8 processors installed 24 drives (12 NVMe) Bays 0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22

Backplane connections are as follows:

  • The 4-drive SAS/SATA backplane has one SAS/SATA connector and connects to a supported RAID controller or SAS HBA installed in the dedicated storage adapter slot.
  • The 4-drive AnyBay backplane has one SAS/SATA connector and connects to a supported RAID controller or SAS HBA plus one NVMe connector to connect to NVMe ports on one of the system boards in a compute tray or directly on the storage tray.

The SAS/SATA backplane is shown in the following figure.

SAS/SATA backplane
Figure 13. SAS/SATA backplane

Adapters and cabling

Each compute tray or storage tray includes one dedicated PCIe slot for a RAID adapter or SAS HBA.

Tip: The adapters are described in detail in the Controllers for internal storage section.

SAS/SATA backplanes are connected to the RAID adapter or HBA installed in the dedicated slot in that tray. AnyBay backplanes (NVMe support on 2 of the 4 drive bays) are connected to the RAID adapter or HBA or to an NVMe port adjacent to processor on a system board.

The following table lists which processor each SAS/SATA storage adapter and which NVMe port each backplane is connected to. Backplane numbering is shown in Figure 11.

Processor numbering is shown in Figure 7.

Table 28. Processor connectivity for storage adapters and NVMe ports
Configuration Slot
location
4S Performance 4S Performance/
Storage Rich
4S Upgradeable 4S Upgradeable/
Storage Rich
8S Storage Rich
Processors installed 2 (1,2) or 3 (1,2,4) or 4 (1,2,3,4) 2 (1,2) or 3 (1,2,4) or 4 (1,2,3,4) 2 (1,2) or 4 (1,2,3,4) 4 (1,2,5,6) 6 (1,2,3,4,5,7) or 8 (1-8)
Storage adapter slot Upper tray NC 1 NC 5 5
Storage adapter slot Lower tray 1 1 1 1 1
NVMe on backplane 4 Upper tray NC 3* NC NC 7
NVMe on backplane 5 NC 4* NC NC 8*
NVMe on backplane 6 NC 2 NC 6 6*
NVMe on backplane 1 Lower tray 3* 3* 3* NC 3
NVMe on backplane 2 4* 4* 4* NC 4
NVMe on backplane 3 2 2 2 2 2

* In 2, 3 and 6 processor configurations, the following backplanes cannot be AnyBay backplanes:

  • In 2-processor configurations, processors 3 and 4 are not installed; this means drive backplanes 1 and 2 cannot be AnyBay backplanes.
  • In 3-processor configurations, processor 3 is not installed; this means drive backplanes 1 and 4 cannot be AnyBay backplanes
  • In 6-processor configurations, processors 6 & 8 are not installed; this means drive backplanes 5 and 6 cannot be AnyBay backplanes

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.

The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.

There are two M.2 adapters supported, as listed in the following table.

Table 29. M.2 components
Part
number
Feature
code
Description Maximum
supported
7Y37A01092 AUMU ThinkSystem M.2 Enablement Kit
(contains the Single M.2 Boot Adapter; supports 1 drive)
1
7Y37A01093 AUMV ThinkSystem M.2 with Mirroring Enablement Kit
(contains the Dual M.2 Boot Adapter, supports 1 or 2 drives)
1

Supported drives are listed in the Internal drive options section.

For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

SED encryption key management with ISKLM

The server supports self-encrypting drives (SEDs) and FIPS 140-2 drives as described in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution. A Lenovo Feature on Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server.

The following table lists the part numbers and feature codes for the upgrades.

Table 30. FoD upgrades for SKLM support
Part number Feature code Description
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan)
00D9998 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00D9999 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa)
00FP648 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00FP649 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S

Controllers for internal storage

The SR950 supports internal SAS and SATA drives with the addition of a RAID adapter or HBA. The adapter is installed in a dedicated slot in each compute tray. For NVMe support, the server uses NVMe ports that are on the compute system boards or on the storage tray if one is configured.

The following table lists the supported adapters.

Tip: Unlike System x RAID adapters, no upgrades are available for these RAID adapters. All supported functions are included with the base part numbers.

Table 31. Controllers for internal storage
Part number Feature code Description Number
of ports
Maximum
supported
SAS/SATA HBA
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA 8 2
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA 12** 2
RAID adapters
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter 8 2
7Y37A01083* AUNH* ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 8 2
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter 8 2
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter 12** 2
4Y37A09721 B31E ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter 12** 2

* The RAID 730-8i adapter is not available in USA and Canada
** The 430-16i HBA and RAID 930-16i adapter support 12 drives when used in the SR950

The following table compares the functions of the storage adapters.

Table 32. Comparison of internal storage controllers
Feature 430-8i 430-16i RAID 530-8i RAID 730-8i† RAID 930-8i RAID 930-16i
Adapter type HBA HBA RAID controller RAID controller RAID controller RAID controller
Part number 7Y37A01088 7Y37A01089 7Y37A01082 7Y37A01083 7Y37A01084 7Y37A01085
4Y37A09721
Form factor PCIe low profile PCIe low profile PCIe HHHL PCIe low profile PCIe HHHL PCIe HHHL
Controller chip LSI SAS3408 LSI SAS3416 LSI SAS3408 LSI SAS3108 LSI SAS3508 LSI SAS3516
Broadcom equivalent HBA 9400-8i HBA 9400-16i MegaRAID 9440-8i MegaRAID 9361-8i MegaRAID 9460-8i MegaRAID 9460-16i
Host interface PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 16 8 8 8 16
Port connectors 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643)
Drive interface SAS, SATA SAS, SATA SAS, SATA SAS, SATA SAS, SATA SAS, SATA
Drive type HDD, SSD, SED* HDD, SSD, SED* HDD, SED, SSD HDD, SSD HDD, SED, SSD HDD, SED, SSD
Hot-swap drives Yes Yes Yes Yes Yes Yes
Max devices 8 12** 8 8 8 12**
RAID levels No RAID No RAID 0, 1, 10, 5, 50 0, 1, 10, 5, 50 0, 1, 10, 5, 50, 6, 60 0, 1, 10, 5, 50, 6, 60
JBOD mode Yes Yes Yes Yes Yes Yes
Cache No No None 1GB (Standard) 2GB (Standard) 4GB or 8GB
(Standard)
CacheVault cache protection No No No No Yes (Flash) Yes (Flash)
Performance Accelerator (FastPath) No No Yes No Yes Yes
SSD Caching (CacheCade Pro 2.0) No No No No No No
SED support* Yes Yes Yes No Yes Yes

† The RAID 730-8i adapter is not available in USA and Canada
* SED (self-encrypting drive) support of the SAS HBAs is by using software on the server (SED commands are passed through the HBA to the drives). SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.
** With the SR950, the 430-16i HBA and RAID 930-16i support up to 12 drives.

Internal drive options

The following tables list the hard disk drive and solid-state drive options for the internal disk storage of the server.

Tip: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

Table 33. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD 24
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD 24
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD 24
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD 24
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD 24
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD 24
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD 24
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD 24
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD 24
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD 24
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD 24
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00030 AUM4 ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED 24
7XB7A00031 AUM5 ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED 24
7XB7A00070 B0YV ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD FIPS 24
Table 34. 2.5-inch hot-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD 24
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD 24
Table 35. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Capacity
7N47A00121 AUMK ThinkSystem 2.5" PM1633a 3.84TB Capacity SAS 12Gb Hot Swap SSD 24
7N47A00122 AUML ThinkSystem 2.5" PM1633a 7.68TB Capacity SAS 12Gb Hot Swap SSD 24
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Performance (10+ DWPD)
7N47A00124 AUMG ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD 24
7N47A00125 AUMH ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD 24
7N47A00126 AVRB ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD 24
2.5-inch hot-swap SSDs - 12 Gb SAS - Enterprise Mainstream (3-5 DWPD)
7N47A00117 AUMC ThinkSystem 2.5" PM1635a 400GB Mainstream SAS 12Gb Hot Swap SSD 24
7N47A00118 AUMD ThinkSystem 2.5" PM1635a 800GB Mainstream SAS 12Gb Hot Swap SSD 24
7N47A00119 AVRG ThinkSystem 2.5" PM1635a 1.6TB Mainstream SAS 12Gb Hot Swap SSD 24
7N47A00120 AVRJ ThinkSystem 2.5" PM1635a 3.2TB Mainstream SAS 12Gb Hot Swap SSD 24
2.5-inch hot-swap SED SSDs - 12 Gb SAS - Enterprise Performance (10+ DWPD)
7SD7A05754 B11P ThinkSystem 2.5" HUSMM32 400GB Performance SAS 12Gb Hot Swap SSD FIPS 24
7SD7A05753 B11Q ThinkSystem 2.5" HUSMM32 800GB Performance SAS 12Gb Hot Swap SSD FIPS 24
7SD7A05752 B11R ThinkSystem 2.5" HUSMM32 1.6TB Performance SAS 12Gb Hot Swap SSD FIPS 24
Table 36. 2.5-inch hot-swap 6 Gb SAS/SATA SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Mainstream (3-5 DWPD)
7SD7A05765 B10W ThinkSystem 2.5" 5100 240GB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05764 B10X ThinkSystem 2.5" 5100 480GB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05763 B10Y ThinkSystem 2.5" 5100 960GB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05762 B10Z ThinkSystem 2.5" 5100 1.92TB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05761 B110 ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05723 B0ZP ThinkSystem 2.5" Intel S4600 240GB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05722 B0ZQ ThinkSystem 2.5" Intel S4600 480GB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05721 B0ZR ThinkSystem 2.5" Intel S4600 960GB Mainstream SATA 6Gb Hot Swap SSD 24
7SD7A05720 B0ZS ThinkSystem 2.5" Intel S4600 1.92TB Mainstream SATA 6Gb Hot Swap SSD 24
2.5-inch hot-swap SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD)
4XB7A10195 B34H ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10196 B34J ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10197 B34K ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10198 B34L ThinkSystem 2.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10199 B34M ThinkSystem 2.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10153 B2X2 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10154 B2X3 ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10155 B2X4 ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10156 B2X5 ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD 24
4XB7A10157 B2X6 ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD 24
7N47A00111 AUUQ ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD 24
7N47A00112 AUM9 ThinkSystem 2.5" PM863a 480GB Entry SATA 6Gb Hot Swap SSD 24
7SD7A05742 B0YY ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD 24
7SD7A05741 B0YZ ThinkSystem 2.5" Intel S4500 480GB Entry SATA 6Gb Hot Swap SSD 24
7SD7A05740 B0Z0 ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD 24
7SD7A05739 B0Z1 ThinkSystem 2.5" Intel S4500 1.92TB Entry SATA 6Gb Hot Swap SSD 24
7SD7A05738 B0Z2 ThinkSystem 2.5" Intel S4500 3.84TB Entry SATA 6Gb Hot Swap SSD 24
4XB7A08503 B10P ThinkSystem 2.5" 5100 960GB Entry SATA 6Gb Hot Swap SSD 24
4XB7A08502 B10N ThinkSystem 2.5" 5100 480GB Entry SATA 6Gb Hot Swap SSD 24
4XB7A08504 B10Q ThinkSystem 2.5" 5100 1.92TB Entry SATA 6Gb Hot Swap SSD 24
4XB7A08505 B10R ThinkSystem 2.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD 24
7N47A00099 AUM8 ThinkSystem 2.5" Intel S3520 240GB Entry SATA 6Gb Hot Swap SSD 24
7N47A00100 AUUZ ThinkSystem 2.5" Intel S3520 480GB Entry SATA 6Gb Hot Swap SSD 24
Table 37. 2.5-inch U.2 NVMe SSDs
Part number Feature Description Maximum
supported
2.5-inch SSDs - NVMe - Enterprise Performance (10+ DWPD)
7N47A00081 AUMJ ThinkSystem U.2 Intel P4800X 375GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 12
7N47A00083 B2ZJ ThinkSystem U.2 Intel P4800X 750GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 12
7XB7A05923 AWG6 ThinkSystem U.2 PX04PMB 800GB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 12
7XB7A05922 AWG7 ThinkSystem U.2 PX04PMB 1.6TB Performance NVMe PCIe 3.0 x4 Hot Swap SSD 12
2.5-inch SSDs - NVMe - Enterprise Mainstream (3-5 DWPD)
7N47A00095 AUUY ThinkSystem U.2 PX04PMB 960GB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 12
7N47A00096 AUMF ThinkSystem U.2 PX04PMB 1.92TB Mainstream NVMe PCIe 3.0 x4 Hot Swap SSD 12
7SD7A05772 B11J ThinkSystem U.2 Intel P4600 1.6TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 12
7SD7A05771 B11K ThinkSystem U.2 Intel P4600 3.2TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 12
7SD7A05770 B11L ThinkSystem U.2 Intel P4600 6.4TB Mainstream NVMe PCIe3.0 x4 Hot Swap SSD 12
2.5-inch SSDs - NVMe - Enterprise Entry (<3 DWPD)
4XB7A10175 B34N ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 12
4XB7A10176 B34P ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 12
7N47A00984 AUV0 ThinkSystem U.2 PM963 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 12
7N47A00985 AUUU ThinkSystem U.2 PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 12
7SD7A05779 B11C ThinkSystem U.2 Intel P4500 1.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 12
7SD7A05778 B11D ThinkSystem U.2 Intel P4500 2.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 12
7SD7A05777 B11E ThinkSystem U.2 Intel P4500 4.0TB Entry NVMe PCIe3.0 x4 Hot Swap SSD 12

Note: NVMe PCIe SSDs support informed hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 38. M.2 drives
Part number Feature Description Maximum
supported
M.2 SSDs - 6 Gb SATA - Enterprise Entry (<3 DWPD)
7N47A00129 AUUL ThinkSystem M.2 CV1 32GB SATA 6Gbps Non-Hot-Swap SSD 2
7N47A00130 AUUV ThinkSystem M.2 CV3 128GB SATA 6Gbps Non-Hot-Swap SSD 2
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot-Swap SSD 2

Internal backup units

The server does not support any internal backup units.

Optical drives

The server does not support an internal optical drive.

An external USB optical drive is available, listed in the following table.

Table 39. External optical drive
Part number Feature code Description
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive

I/O expansion options

The server supports the following PCIe slots, depending on the server configuration selected:

  • Slots 1-17 are PCIe 3.0 slots accessible from the rear of the server
  • One internal dedicated M.2 slot for an M.2 adapter located internally on the I/O tray
  • Two internal dedicated PCIe 3.0 x8 slots for storage adapters, located internally in each compute tray or storage tray

The following figure shows the locations of the slots at the rear of the server.

PCIe 3.0 slots at the rear of the server
Figure 14. PCIe 3.0 slots at the rear of the server

The 17 PCIe 3.0 rear-accessible slots are as follows:

  • Slots 1-4 are via Riser Slot 1, one riser card of:
    • Riser with 4x PCIe 3.0 x16 slots, all full-height half-length, all 75W
    • Riser with 2x PCIe 3.0 x16 slots, all full-height half-length, both 75W
    • Riser with 4x PCIe 3.0 x8 slots, full-height half-length, all 75W
  • Slot 5: PCIe 3.0 x16, low profile, 75W
  • Slot 6: PCIe 3.0 x16, low profile, 75W
  • Slot 7: PCIe 3.0 x8, low profile, 75W
  • Slot 8: PCIe 3.0 x16 ML2, low profile (supports NC-SI)
  • Slot 9: PCIe 3.0 x8 LOM adapter slot, low profile (supports NC-SI)
  • Slots 10-15 are via Riser Slot 2, one riser card of:
    • Riser 5x16+ML2
      • Five PCIe 3.0 x16 slots, all full-height half-length, all 75W
      • One PCIe 3.0 x16 ML2 slot, full-height half-length, 30W (no NC-SI support)
    • Riser 2x16: Two PCIe 3.0 x16 slots, all full-height half-length, both 75W
    • Riser 4x8: Four PCIe 3.0 x8 slots, full-height half-length, all 75W
  • Slot 16-17 on a riser:
    • PCIe 3.0 x8 low profile, 75W
    • PCIe 3.0 x8 low profile, 75W

Additional internal PCIe slots:

  • One or two PCIe 3.0 x8 slots for storage adapters, one in each compute tray
  • M.2 adapter slot

NC-SI (Network Controller Sideband Interface or NCSI) support means the primary port on the adapter installed in that slot can be configured as shared between XCC out-of-band management traffic and production Ethernet traffic.

For riser slots 1 and 2, the server supports the following three riser cards. These are shown in the figure below.

  • Riser 5x16+ML2:
    • Five PCIe 3.0 x16 slots, all full-height half-length, all 75W
    • One PCIe 3.0 x16 ML2 slot, full-height half-length, 30W (no NC-SI support)

    Note: When the 5x16+ML2 riser is installed in riser slot 1, the bottom two slots (including the ML2) are not accessible and cannot be used.

  • Riser 2x16: Two PCIe 3.0 x16 slots, all full-height half-length, both 75W
  • Riser 4x8: Four PCIe 3.0 x8 slots, full-height half-length, all 75W

Note: The ML2 slot on the riser card does not support NC-SI.

Riser cards for riser slots 1 and 2
Figure 15. Riser cards for riser slots 1 and 2

Slot numbering is as follows:
  • When installed in riser slot 1:
    • Riser 5x16+ML2 becomes slots 1-4 (bottom two slots inaccessible)
    • Riser 2x16 becomes slots 3-4
    • Riser 4x8 becomes slots 1-4
  • When installed in riser slot 2:
    • Riser 5x16+ML2 becomes slots 10-15
    • Riser 2x16 becomes slots 12-13
    • Riser 4x8 becomes slots 10-13

Note: When the 5x16+ML2 riser card is used in Riser slot 1, only the top 4 slots (all x16) are accessible. The lower x16 and x16 ML2 slots cannot physically be accessed or used.

Slots 16 and 17 are mounted on a single 2x8 riser card and are as follows:

  • Slot 16: PCIe 3.0 x8, full-height half-length, 75W
  • Slot 17: PCIe 3.0 x8, full-height half-length, 75W

The 2x8 riser card is shown below.

2x8 Riser Card
Figure 16. 2x8 riser card

Ordering information for the riser cards is listed in the following table.

Table 40. Riser card ordering information
Part
number
Feature
code
Description
Riser cards for riser slots 1 and 2
7XC7A03963 AUN3 ThinkSystem SR950 up to (5) x16 + x16 ML2 PCIe Riser
7XC7A03961 AUN1 ThinkSystem SR950 (2) x16 PCIe Riser
7XC7A03962 AUN2 ThinkSystem SR950 (4) x8 PCIe Riser
Riser card for 2x8 riser slot
7XC7A03964 AUN4 ThinkSystem SR950 (2) x8 PCIe Riser

Slot availability by server configuration

The riser cards required for each server configuration are listed in the following table. See the Server configurations section for details.

Table 41. Riser card requirements
Riser 4S Performance 4S Performance/
Storage Rich
4S Upgradeable 4S Upgradeable/
Storage Rich
8S Storage Rich
Riser 1 4x8 or 2x16 4x8 or 2x16 4x8 or 2x16 5x16+ML2* 5x16+ML2*
Riser 2 4x8 or 2x16 4x8 or 2x16 4x8 or 2x16 5x16+ML2* 5x16+ML2*
2x8 Riser 2x8 None 2x8 2x8 2x8

* If desired, the 4x8 or 2x16 riser cards can be used instead of the 5x16+ML2 riser, with reduced slot availability

Based on these riser card requirements, the available slots for each server configuration are highlighted with a grey background in the following table. The table also lists the processor that each PCIe slot is connected to, based on the server configuration selected. In the table, NC means not connected.

Processor numbering is shown in Figure 7.

Table 42. Processor connectivity for PCIe slots (NC = not connected)
Configuration Slot
location
4S Performance 4S Performance/
Storage Rich
4S Upgradable 4S Upgradable/
Storage Rich
8S Storage Rich
Processors installed 2 (1,2) or 3 (1,2,4) or 4 (1,2,3,4) 2 (1,2) or 3 (1,2,4) or 4 (1,2,3,4) 2 (1,2) or 4 (1,2,3,4) 4 (1,2,5,6) 6 (1,2,3,4,5,7) or 8 (1-8)
Slot 1 Riser 1 4**
(NC for 2x16)*
4**
(NC for 2x16)*
4**
(NC for 2x16)*
NC 8**
Slot 2 4**
(NC for 2x16)*
4**
(NC for 2x16)*
4**
(NC for 2x16)*
NC 8**
Slot 3 4** 4** 4** 6 6**
Slot 4 4** 4** 4** 6 6**
Slot 5 I/O Tray 2 2 2 2 2
Slot 6 I/O Tray 2 2 2 2 2
Slot 7 I/O Tray 1 1 1 1 1
Slot 8 (ML2) I/O Tray 1 1 1 1 1
Slot 9 (LOM) I/O Tray 1 (PCH) 1 (PCH) 1 (PCH) 1 (PCH) 1 (PCH)
Slot 10 Riser 2 3** 3** 3** NC 7
Slot 11 3** 3** 3** NC 7
Slot 12 3** 3** 3** 5 5
Slot 13 3** 3** 3** 5 5
Slot 14 NC NC NC NC 3
Slot 15 (ML2) NC NC NC NC 3
Slot 16 2x8 Riser 3** NC 3** NC 3
Slot 17 1 NC 1 1 1
M.2 slot I/O Tray 1 (PCH) 1 (PCH) 1 (PCH) 1 (PCH) 1 (PCH)
Storage adapter slot Upper tray NC 1 NC 5 5
Storage adapter slot Lower tray 1 1 1 1 1

* Slots 1 and 2 are not connected if the 2x16 riser card is used in riser slot 1
** In 2, 3 and 6 processor configurations, the following slots are not available:

  • In 2-processor configurations, processors 3 and 4 are not installed; this means slots 1-4, slots 10-13, and slot 16 are not connected
  • In 3-processor configurations, processor 3 is not installed; this means slots 10-13, and slot 16 are not connected
  • In 6-processor configurations, processors 6 & 8 are not installed; this means slots 1-4 are not connected

Network adapters

The SR950 has an integrated 10Gb Ethernet controller, based on the Intel Ethernet Connection X722. The X722 has the following features:

  • Integrated into the Intel PCH chipset
  • Supports 1GbE or 10GbE connections, depending on the selected LOM Phy adapter
  • Offers VXLAN/NVGRE hardware offloads
  • Supports VMDq and SR-IOV for advanced virtualization
  • Supports iWarp RDMA

To provide connectivity to the X722, the SR950 supports six different LOM (LAN on Motherboard) cards which provide the Ethernet PHY function. Only 1 LOM card can be installed. See Figure 3 for the location of the LOM slot.

The LOM card supports NC-SI to allow the network connection to be shared between the operating system and the XClarity Controller (XCC) management module. The LOM also supports Wake-on-LAN (WOL).

For more information about the X722 controller, see the Lenovo Press product guide:
http://lenovopress.com/lp0654-intel-x722-integrated-controller

The following table lists the supported LOM cards.

Note: None of the LOM cards listed in the table support speeds lower than 1 Gbps.

Table 43. Supported LOM adapters
Part
number
Feature
code
Description Ports Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00544 AUKG ThinkSystem 1Gb 2-port RJ45 LOM 2x RJ45 9 1
7ZT7A00545 AUKH ThinkSystem 1Gb 4-port RJ45 LOM 4x RJ45 9 1
10 Gb Ethernet
7ZT7A00546 AUKJ ThinkSystem 10Gb 2-port SFP+ LOM 2x SFP+ bays 9 1
7ZT7A00547 AUKK ThinkSystem 10Gb 4-port SFP+ LOM 4x SFP+ bays 9 1
7ZT7A00548 AUKL ThinkSystem 10Gb 2-port Base-T LOM 2x RJ45 (10GBASE-T) 9 1
7ZT7A00549 AUKM ThinkSystem 10Gb 4-port Base-T LOM 4x RJ45 (10GBASE-T) 9 1

The SR950 also support one ML2 card for 4-socket configurations (slot 8). For 8-socket servers using the 5x16 ML2 riser, the server has two ML2 slots - slot 8 and slot 15. See the I/O expansion options section for details.

The ML2 card in slot 8 supports NC-SI however the ML2 card in slot 15 does not support NC-SI.

The following table lists the supported ML2 adapters.

Table 44. Supported ML2 adapters
Part
number
Feature
code
Description Bus width Slots
supported
Maximum
supported†
Gigabit Ethernet
7ZT7A00536 AUKW ThinkSystem Intel I350-T4 ML2 1Gb 4-Port RJ45 Ethernet Adapter PCIe 3.0 x8 8, 15 1 / 2
10 Gb Ethernet
00JY940 ATRH Intel X710-DA2 ML2 2x10GbE SFP+ Adapter PCIe 3.0 x8 8, 15 1 / 2
7ZT7A00497 AUKQ ThinkSystem Broadcom NX-E ML2 10Gb 2-Port Base-T Ethernet Adapter PCIe 3.0 x8 8, 15 1 / 2
00AG560* AT7U Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter PCIe 3.0 x8 8, 15 1 / 2
01CV770 AU7Z Emulex VFA5.2 ML2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW PCIe 3.0 x8 8, 15 1 / 2
25 Gb Ethernet
7ZT7A00507 AUKU ThinkSystem Mellanox ConnectX-4 Lx ML2 25Gb 2-Port SFP28 Ethernet Adapter PCIe 3.0 x8 8, 15 1 / 2
00MN990 ATZR Mellanox ConnectX-4 Lx ML2 1x25GbE SFP28 Adapter PCIe 3.0 x8 8, 15 1 / 2
InfiniBand
7ZT7A00501 AUKR ThinkSystem Mellanox ConnectX-3 Pro ML2 FDR 2-Port QSFP VPI Adapter PCIe 3.0 x8 8, 15 1 / 2

* ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter, 00AG560, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support, use 01CV770 instead.
† Two ML2 adapters are supported with an 8-socket configuration if the 5x16+ML2 riser is installed in riser slot 2.

The following table lists additional supported network adapters that can be installed in the regular PCIe slots.

Table 45. Supported PCIe Network Adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00482 AUZX ThinkSystem NetXtreme PCIe 1Gb 2-Port RJ45 Ethernet Adapter 1-7, 10-14, 16-17 14
7ZT7A00484 AUZV ThinkSystem Broadcom NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter 1-7, 10-14, 16-17 14
7ZT7A00533 AUZZ ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter 1-7, 10-14, 16-17 14
7ZT7A00534 AUZY ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter 1-7, 10-14, 16-17 14
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter 1-7, 10-14, 16-17 14
10 Gb Ethernet - 10GBase-T
7ZT7A00496 AUKP ThinkSystem Broadcom NX-E PCIe 10Gb 2-Port Base-T Ethernet Adapter 1-7, 10-14, 16-17 14
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter 1-7, 10-14, 16-17 14
4XC7A08225 B31G ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter 1-7, 10-14, 16-17 14
10 Gb Ethernet - SFP+
7ZT7A00537 AUKX ThinkSystem X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter 1-7, 10-14, 16-17 14
7ZT7A00493 AUKN ThinkSystem Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter 1-4, 10-14 9
00AG570* AT7S Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter 1-7, 10-14, 16-17 14
00AG580 AT7T Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW 1-7, 10-14, 16-17 14
25 Gb Ethernet
4XC7A08228 B21R ThinkSystem QLogic QL41262 PCIe 25Gb 2-Port SFP28 Ethernet Adapter 1-7, 10-14, 16-17 14
7XC7A05523 B0WY ThinkSystem Intel XXV710-DA2 PCIe 25Gb 2-Port SFP28 Ethernet Adapter 1-7, 10-14, 16-17 14
7ZT7A00505 AUKS ThinkSystem Broadcom NX-E PCIe 25Gb 1-Port SFP28 Ethernet Adapter 1-7, 10-14, 16-17 14
01GR250 AUAJ Mellanox ConnectX-4 Lx 2x25GbE SFP28 Adapter 1-7, 10-14, 16-17 14
4XC7A08229 B31C ThinkSystem Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter 1-6, 10-14 11
40 Gb Ethernet
00MM950 ATRN Mellanox ConnectX-4 Lx 1x40GbE QSFP+ Adapter 1-7, 10-14, 16-17 14
4XC7A08229 B31C ThinkSystem Mellanox ConnectX-5 Ex 25/40GbE 2-port Low-Latency Adapter 1-6, 10-14 11
100 Gb Ethernet
00KH924 ASWQ Mellanox ConnectX-4 1x100GbE/EDR IB QSFP28 VPI Adapter 1-6, 10-14 11
00MM960 ATRP Mellanox ConnectX-4 2x100GbE/EDR IB QSFP28 VPI Adapter 1-6, 10-14 11
InfiniBand
7ZT7A00500 AUVG ThinkSystem Mellanox ConnectX-4 PCIe FDR 2-Port QSFP VPI Adapter 1-7, 10-14, 16-17 14
Omni-Path Architecture
00WE023 AU0A Intel OPA 100 Series Single-port PCIe 3.0 x8 HFA 1-7, 10-14, 16-17 14
00WE027 AU0B Intel OPA 100 Series Single-port PCIe 3.0 x16 HFA 1-6, 10-14 11

* ThinkSystem servers do not support Features on Demand, so the Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter, 00AG570, cannot be upgraded to FCoE support. If you need FCoE or iSCSI support, use 00AG580 instead.

For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Networking adapters category:
https://lenovopress.com/servers/options/ethernet

Fibre Channel host bus adapters

The following table lists the Fibre Channel HBAs supported by SR950.

Table 46. Fibre Channel HBAs
Part
number
Feature
code
Description Slots
supported
Maximum
supported
32 Gb Fibre Channel HBAs
7ZT7A00516 AUNS ThinkSystem QLogic QLE2740 PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter 1-7, 10-14, 16-17 14
7ZT7A00518 AUNU ThinkSystem QLogic QLE2742 PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter 1-7, 10-14, 16-17 14
7ZT7A00519 AUNV ThinkSystem Emulex LPe32002-M2-L PCIe 32Gb 2-Port SFP+ Fibre Channel Adapter 1-7, 10-14, 16-17 14
7ZT7A00517 AUNT ThinkSystem Emulex LPe32000-M2-L PCIe 32Gb 1-Port SFP+ Fibre Channel Adapter 1-7, 10-14, 16-17 14
16 Gb Fibre Channel HBAs
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA 1-7, 10-14, 16-17 14
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA 1-7, 10-14, 16-17 14
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA 1-7, 10-14, 16-17 14
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA 1-7, 10-14, 16-17 14

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba

SAS adapters for external storage

The following table lists SAS HBAs and RAID adapters supported by SR950 server for use with external storage.

Table 47. Adapters for external storage
Part
number
Feature
code
Description Slots
supported
Maximum
supported
SAS HBAs
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA 1-7, 10-14, 16-17 14
7Y37A01091 AUNN ThinkSystem 430-16e SAS/SATA 12Gb HBA 1-7, 10-14, 16-17 14
External RAID adapters
7Y37A01087 AUNQ ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter 1-7, 10-14, 16-17 Four*

* Maximum is 4 adapters because there are only 4 supercap holders in the server, mounted on the side of the two riser cards.

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters and RAID adapters categories:
https://lenovopress.com/servers/options/hba
https://lenovopress.com/servers/options/raid

The following table compares the specifications of the external SAS HBAs and RAID adapters.

Table 48. Comparison of external storage adapters
Feature 430-8e 430-16e 930-8e
Adapter type HBA HBA External RAID
Part number 7Y37A01090 7Y37A01091 7Y37A01087
Controller chip LSI SAS3408 LSI SAS3416 LSI SAS3508
Broadcom equivalent HBA 9400-8e HBA 9400-16e MegaRAID 9480-8e
Host interface PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 16 8
Port connectors 2x Mini-SAS HD SFF8644 4x Mini-SAS HD SFF8644 2x Mini-SAS HD SFF8644
Drive interface SAS/SATA SAS/SATA SAS,SATA
Drive type HDD/SSD/SED* HDD/SSD/SED* HDD,SED,SSD
Hot-swap drives Yes Yes Yes
Maximum devices 512 (planned: 1024) 512 (planned: 1024) 64 (planned: 216)
RAID levels None None 0/1/10/5/50/6/60
JBOD mode Yes Yes Yes
Cache None None 4GB (Standard)
CacheVault cache protection None None Yes (Flash)
Performance Accelerator (FastPath) No No Yes
SSD Caching (CacheCade Pro 2.0) No No No
SED support* Yes Yes Yes

* SED support of the SAS HBAs is by using software on the server (SED commands are passed through the HBA to the drives). SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.

Flash storage adapters

The server supports the PCIe Flash Storage adapters listed in the following table.

Table 49.
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Entry NVMe PCIe Adapters - Optimized for read-intensive workloads with an endurance of less than 3 DWPD.
7SD7A05776 B11Z ThinkSystem HHHL Intel P4500 4.0TB Entry NVMe PCIe3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14
7SD7A05775 B120 ThinkSystem HHHL Intel P4500 8.0TB Entry NVMe PCIe3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14
Mainstream NVMe PCIe Adapters - Optimized for mixed-intensive application workloads with an endurance of 3-5 DWPD.
7SD7A05769 B11X ThinkSystem HHHL Intel P4600 2.0TB Mainstream NVMe PCIe3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14
7SD7A05768 B11Y ThinkSystem HHHL Intel P4600 4.0TB Mainstream NVMe PCIe3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14
7N47A00097 AUUP ThinkSystem HHHL PX04PMC 1.92TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14
7N47A00098 AUVY ThinkSystem HHHL PX04PMC 3.84TB Mainstream NVMe PCIe 3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14
Performance NVMe PCIe Adapters - Optimized for write-intensive application workloads with an endurance of 10+ DWPD.
7XB7A05925 AWG8 ThinkSystem HHHL PX04PMC 1.6TB Performance NVMe PCIe 3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14
7XB7A05924 AWG9 ThinkSystem HHHL PX04PMC 3.2TB Performance NVMe PCIe 3.0 x4 Flash Adapter 1-7, 10-14, 16-17 14

For details about these adapters, see the Lenovo Press product guides in the Flash Adapters category:
https://lenovopress.com/servers/options/ssdadapter

GPU adapters and coprocessors

Full-length adapter cards such as graphics processing units (GPUs) do not physically fit in the server and are not supported.

Cooling

The SR950 uses a set of 60mm hot-swap single-rotor fans for system-wide cooling. Each compute tray or storage tray houses 6 hot-swap fans. The 6 fans in the compute tray are N+1 redundant, meaning that a single fan failure is tolerated in each compute tray.

Fans are located internal to the server immediately in front of the compute system boards, but are accessible from the front of the server by the long handle attached to the fan. As the handle is pulled out, the attached fan rotates from vertical orientation to horizontal orientation, allowing the fan to be removed from the system using the handle, as shown below.

Six fans installed in the compute tray
Figure 17. Six fans installed in each compute tray (lower compute tray shown)

 

Power supplies

The server supports up to four hot-swap power supplies. Power supplies are N+N redundant, which means that if the server has four power supplies installed, then the server can continue operation even with two failed power supplies, or if the utility service that feeds those two power supplies goes offline.

All power supplies installed in a server must have the same capacity (for example all 1600W).

Table 50. Power supply options
Part number Feature
code
Description Maximum
supported
110V AC 220V AC 240V DC
China only
7N67A00885 AVNV 1100W Platinum (230V/115V) Power Supply 4 Yes Yes No
7N67A00886 AUPT 1600W Platinum (230V) Power Supply 4 No Yes No

The 1100W power supply is auto-sensing and supports both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. The 1600 W power supply only supports 220V AC power. 240V DC is not supported.

Note: At 100-127 V AC input, the 1100W power supply is limited to 1050W.

Power supply options do not include a power cord. For models of the SR950, the inclusion of a power cords is model dependent. Configure-to-order models can be configured without a power cord if desired.

Tip: Use Lenovo Capacity Planner to determine exactly what power your server needs:
https://datacentersupport.lenovo.com/us/en/products/solutions-and-software/software/lenovo-capacity-planner/solutions/ht504651

Power cords

Country-specific line cords and rack power cables can be ordered as listed in the following table.

110V customers: If you plan to use the ThinkSystem 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

Table 51. Power cords
Part number Feature code Description
Rack cables
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Jumper Cord
Country-specific cables
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
39Y7928 6210 2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/250V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
81Y2376 6572 4.3m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13 to IS 6538 (India) Line Cord
81Y2386 6567 4.3m, 10A/250V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/250V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
81Y2380 6493 4.3m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164-1 (South Africa) Line Cord
81Y2379 6576 4.3m, 10A/250V, C13 to SANS 164-1 (South Africa) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7925 6219 2.8m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
81Y2385 6494 4.3m, 12A/250V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8M, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
00WH545 6401 2.8M, 13A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/125V, C13 to NEMA 5-15P (US) Line Cord

Integrated virtualization

The server supports booting from an operating system or hypervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.

You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
https://vmware.lenovo.com/content/custom_iso/

Systems management

The server contains an integrated service processor, XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. The XCC is based on the Pilot4 XE401 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.

Local management

The SR950 offers the front operator panel showing key LED status indicators, as shown in the following figure.

Front operator panel
Figure 18. Front operator panel (LCD display panel closed)

The front operator panel pulls out (see the release latch in the above figure) to show an LCD display panel and buttons, as shown in the following figure. The LCD display panel allows quick access to system status, firmware, network, and health information.

Front operator panel with LCD display
Figure 19. LCD display panel

The LCD display and the function buttons give you access to the following information:

  • Error messages
  • System VPD: machine type & mode, serial number, UUID string
  • System firmware levels: UEFI and XCC firmware
  • XCC network information: hostname, MAC address, IP address, DNS addresses
  • Environmental data: Ambient temperature, CPU temperature, AC input voltage, estimated power consumption
  • System reset action

If an environmental condition exceeds a threshold or if a system component fails, XCC lights LEDs inside the server to help you diagnose the problem and find the failing part. The SR950 has fault LEDs next to the following components:

  • Each processor
  • Each memory DIMM
  • Each system fan
  • Each power supply
  • Each rear-facing PCIe slot 
  • Each drive bay

For local console use, the SR950 has both a front and rear VGA port. Only one can be active at a time. If displays are connected to both VGA ports, the front VGA port takes precedence. 

System status with XClarity Mobile

The XClarity Mobile app now includes a tethering function where you can connect your Android or iOS device to the server via USB to see the status of the server.

The steps to connect the mobile device are as follows:

  1. Enable USB Management on the server, by holding down the ID button for 3 seconds (or pressing the dedicated USB management button if one is present)
  2. Connect the mobile device via a USB cable to the server's USB port with the management symbol USB Management symbol
  3. In iOS or Android settings, enable Personal Hotspot or USB Tethering
  4. Launch the Lenovo XClarity Mobile app

Once connected you can see the following information:

  • Server status including error logs (read only, no login required)
  • Server management functions (XClarity login credentials required)

Remote management

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SMNP v1)
  • Common Information Model (CIM-XML)
  • Representational State Transfer (REST) support
  • Redfish support (DMTF compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for the device being used: laptop, tablet, phone) with NLS support

A virtual presence (remote control and remote media) capability also comes standard in the server for remote server management.

The remote control functions include the following:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Capturing blue-screen errors
  • International keyboard mapping support
  • LDAP-based authentication
  • Optionally, with the XCC Enterprise license upgrade, mapping ISO and diskette IMG image files as virtual drives that are available for use by the server
  • Boot Capture
  • Remote mounting of ISO and IMG files
  • Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
  • Power capping
  • License for XClarity Energy Manager

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions.

Lenovo XClarity Administrator provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator provides full management function to ThinkSystem servers, including the following:

  • Discovery
  • Inventory
  • Monitoring and alerting
  • Call home
  • Centralized user management
  • Cryptography modes, server certificates, and encapsulation
  • Configuration patterns
  • Operating system deployment
  • Firmware updates

For more information about Lenovo XClarity Administrator, including ordering part numbers, see the Lenovo XClarity Administrator Product Guide:
https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system setting, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager is an agent-free, web-based console that provides power management for ThinkSystem servers as well as System x and ThinkServer systems. It enables server density and data center capacity to be increased through the use of power capping.

Lenovo XClarity Energy Manager is a licensed product. A single-node XClarity Energy Manager license is included with the XClarity Controller Enterprise (XCC Enterprise) upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 52. Lenovo XClarity Energy Manager
Description Part number Maximum supported
4L40E51621 Lenovo XClarity Energy Manager Node License 1 node
4L40E51622 Lenovo XClarity Energy Manager Node License Pack 5 nodes
4L40E51623 Lenovo XClarity Energy Manager Node License Pack 50 nodes

Security

The server offers the following security features:

  • Administrator and power-on password
  • Trusted Platform Module (TPM) supporting both TPM 1.2 and TPM 2.0
  • Optional Trusted Cryptographic Module (TCM) or Nationz TPM, available only in China
  • Self-encrypting drives with support for IBM Security Key Lifecycle Manager

The plugin TCM and NationZ TPM modules, available only for China customers, are installed in a dedicated socket on the I/O tray, as shown in Figure 9. Ordering information is shown in the following table.

Table 53. Security features
Part number Feature code Description
None* AVKE ThinkSystem Trusted Cryptographic Module (China customers only)
None* B22N ThinkSystem Nationz Trusted Platform Module v2.0

* The component is CTO on pre-configured models only. Not available as a field upgrade.

For SED drives and IBM Security Key Lifecycle Manager support see the SED encryption key management with ISKLM section.

Rack installation

All models of the SR950 include a rail kit for installation in a 19-inch rack cabinet. The contents of the kits are shown in the following figure.

SR950 rail kit
Figure 20. SR950 rail kit

Optionally available is the SR950 shipping bracket kit, which is used when the server is installed in a rack and the complete rack is then shipped to the client.

Shipping bracket kit
Figure 21. SR950 shipping bracket kit

Table 54. Shipping bracket kit
Part number Feature code Description
7XF7A03967 AUL5 ThinkSystem SR950 Shipping Bracket

Operating system support

The SR950 supports the following operating systems:

  • Microsoft Windows Server 2012 R2
  • Microsoft Windows Server 2016
  • Microsoft Windows Server, version 1709
  • Microsoft Windows Server, version 1803
  • Red Hat Enterprise Linux 6.10 x64
  • Red Hat Enterprise Linux 6.9 x64
  • Red Hat Enterprise Linux 7.3
  • Red Hat Enterprise Linux 7.4
  • Red Hat Enterprise Linux 7.5
  • SUSE Linux Enterprise Server 11 x64 SP4
  • SUSE Linux Enterprise Server 12 SP2
  • SUSE Linux Enterprise Server 12 SP3
  • SUSE Linux Enterprise Server 15
  • SUSE Linux Enterprise Server 15 Xen
  • VMware ESXi 6.0 U3
  • VMware ESXi 6.5
  • VMware ESXi 6.5 U1
  • VMware ESXi 6.5 U2
  • VMware ESXi 6.7

Note: Support for RHEL 6.9 on the SR950 is limited to up to 4 processors. Configurations greater than 4 processors are not supported.

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig#servers=sr950-7x11-7x12-7x13

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 55. VMware ESXi preload
Part number Feature code Description
CTO only AXFT VMware ESXi 6.5 (factory installed)
CTO only AXFS VMware ESXi 6.0 U3 (factory installed)

Physical and electrical specifications

Dimensions and weight:

  • Height: 173 mm (6.8 in.)
  • Depth:
    • EIA flange to rear: 800.0 mm (31.5 in.)
    • Overall: 835.0 mm (32.9 in.)
  • Width:
    • Top cover: 447.0 mm (17.6 in.)
    • EIA flange: 482.0 mm (19.0 in.)
  • Weight:
    • Minimum configuration: 32.6 kg (71.9 lb)
    • Maximum configuration: 58.7 kg (129.4 lb)

Electrical:

  • Models with 1600 W AC power supplies:
    • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 9.0 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.16 kVA
      • Maximum configuration: 7.2 kVA
  • Models with 1100 W AC power supplies:
    • 100 - 127 (nominal) V AC; 50 Hz or 60 Hz; 11.9 A
    • 200 - 240 (nominal) V AC; 50 Hz or 60 Hz; 6.2 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.12 kVA
      • Maximum configuration: 4.9 kVA

Operating environment

The ThinkSystem SR950 server is designed to ensure thermal compliance to ASHRAE A4 ambient environments, however certain processor models and other components will limit support to only ASHRAE A2 conditions, as shown in the following table. Further, some high-end processors (as indicated with an * in the table) when used in an eight-socket configuration may experience a slight drop in performance under extreme workloads when the ambient temperature is above 30°C.

The following restrictions also apply regarding ASHRAE A3 and A4 support:

  • NVMe drives and adapters are supported up to 35°C only
Table 56. ASHRAE support by processor
Processor ASHRAE A2
support
ASHRAE A3
support
ASHRAE A4
support
Intel Xeon Gold 5115 10C 85W 2.4GHz Processor Yes Yes Yes
Intel Xeon Gold 5117 14C 105W 2.0GHz Processor Yes Yes Yes
Intel Xeon Gold 5118 12C 105W 2.3GHz Processor Yes Yes Yes
Intel Xeon Gold 5119T 14C 85W 1.8GHz Processor Yes Yes Yes
Intel Xeon Gold 5120 14C 105W 2.2GHz Processor Yes Yes Yes
Intel Xeon Gold 5120T 14C 105W 2.2GHz Processor Yes Yes Yes
Intel Xeon Gold 5122 4C 105W 3.6GHz Processor Yes Yes Yes
Intel Xeon Gold 6126 12C 125W 2.6GHz Processor Yes Yes Yes
Intel Xeon Gold 6126T 12C 125W 2.6GHz Processor Yes Yes Yes
Intel Xeon Gold 6128 6C 115W 3.4GHz Processor Yes Yes Yes
Intel Xeon Gold 6130 16C 125W 2.1GHz Processor Yes Yes Yes
Intel Xeon Gold 6130T 16C 125W 2.1GHz Processor Yes Yes Yes
Intel Xeon Gold 6132 14C 140W 2.6GHz Processor Yes Yes Yes
Intel Xeon Gold 6134 8C 130W 3.2GHz Processor Yes Yes Yes
Intel Xeon Gold 6134M 8C 130W 3.2GHz Processor Yes Yes Yes
Intel Xeon Gold 6136 12C 150W 3.0GHz Processor Yes No No
Intel Xeon Gold 6138 20C 125W 2.0GHz Processor Yes Yes Yes
Intel Xeon Gold 6138T 20C 125W 2.0GHz Processor Yes Yes Yes
Intel Xeon Gold 6140 18C 140W 2.3GHz Processor Yes Yes Yes
Intel Xeon Gold 6140M 18C 140W 2.3GHz Processor Yes Yes Yes
Intel Xeon Gold 6142 16C 150W 2.6GHz Processor Yes No No
Intel Xeon Gold 6142M 16C 150W 2.6GHz Processor Yes No No
Intel Xeon Gold 6144 8C 145W 3.5GHz Processor Yes No No
Intel Xeon Gold 6146 12C 165W 3.2GHz Processor Yes No No
Intel Xeon Gold 6148 20C 150W 2.4GHz Processor Yes No No
Intel Xeon Gold 6150 18C 165W 2.7GHz Processor Yes No No
Intel Xeon Gold 6152 22C 140W 2.1GHz Processor Yes Yes Yes
Intel Xeon Gold 6154 18C 200W 3.0GHz Processor Yes No No
Intel Xeon Platinum 8153 16C 125W 2.0GHz Processor Yes Yes Yes
Intel Xeon Platinum 8156 4C 105W 3.6GHz Processor Yes Yes Yes
Intel Xeon Platinum 8158 12C 150W 3.0GHz Processor Yes No No
Intel Xeon Platinum 8160 24C 150W 2.1GHz Processor Yes No No
Intel Xeon Platinum 8160M 24C 150W 2.1GHz Processor Yes No No
Intel Xeon Platinum 8160T 24C 150W 2.1GHz Processor Yes No No
Intel Xeon Platinum 8164 26C 150W 2.0GHz Processor Yes No No
Intel Xeon Platinum 8168 24C 205W 2.7GHz Processor Yes* No No
Intel Xeon Platinum 8170 26C 165W 2.1GHz Processor Yes No No
Intel Xeon Platinum 8170M 26C 165W 2.1GHz Processor Yes No No
Intel Xeon Platinum 8176 28C 165W 2.1GHz Processor Yes No No
Intel Xeon Platinum 8176M 28C 165W 2.1GHz Processor Yes No No
Intel Xeon Platinum 8180 28C 205W 2.5GHz Processor Yes* No No
Intel Xeon Platinum 8180M 28C 205W 2.5GHz Processor Yes* No No

* These processors when used in an eight-socket configuration may experience a slight drop in performance under extreme workloads when the ambient temperature is above 30°C.

The server is supported operating in the following environments:

  • ASHRAE A2:
    • Temperature: 10°C to 35°C
    • Humidity: 20% to 80%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 300 m above 950 m
  • ASHRAE A3:
    • Temperature: 5°C to 40°C
    • Humidity: 8% to 85%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 175 m above 950 m
  • ASHRAE A4:
    • Temperature: 5°C to 45°C
    • Humidity: 8% to 90%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 125 m above 950 m

Non-operating environment support:

  • Without packaging:
    • Temperature: -10 °C to 60 °C
    • Humidity: 8 to 90%
  • Storage with packaging:
    • Temperature: -40 °C to 70 °C
    • Humidity: 8 to 90%

The server generates the following heat:

  • Thermal/heat output:
    • Minimum configuration: 938 BTU/hr, 275 W
    • Typical configuration: 3412 BTU/hr, 1000 W
    • Full configuration: 11,970 BTU/hr, 3508 W

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg  - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Warranty options

The ThinkSystem SR950 server has the following choice of warranties:

  • Machine type 7X11: 1-year warranty
  • Machine type 7X12: 3-year warranty
  • Machine type 7X13: 3-year warranty

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units, FRUs, only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Also available are Lenovo Services warranty maintenance upgrades and post-warranty maintenance agreements, with a predefined scope of services, including service hours, response time, term of service, and service agreement terms and conditions.

Lenovo warranty service upgrade offerings are country-specific. Not all warranty service upgrades are available in every country. For more information about Lenovo warranty service upgrade offerings that are available in your country, go to the Data Center Advisor and Configurator (formerly known as LESC) website http://lesc.lenovo.com, then do the following:

  1. In the Customize a Model box in the middle of the page, select the Services option in the Customization Option dropdown menu
  2. Enter the machine type & model of the system
  3. From the search results, you can click either Deployment Services or Support Services to view the offerings

The following table explains warranty service definitions in more detail.

Table 57. Warranty service definitions
Term Description
Onsite Service If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location. 
Parts Delivered If a problem with your product cannot be resolved via telephone and a CRU part is required, Lenovo will send a replacement CRU to arrive at your location. If a problem with your product cannot be resolved via telephone and a FRU part is required, a Service Technician will be dispatched to arrive at your location.  
Technician Installed Parts If a problem with your product cannot be resolved via telephone, a Service Technician will be dispatched to arrive at your location.
Hours of coverage
  • 9x5: 9 hours/day, 5 days/week, during normal business hours, excluding local public & national holidays
  • 24x7: 24 hours per day, 7 days per week, 365 days per year.
Response time target 2 hours, 4 hours, or Next Business Day: The time period from when the telephone based troubleshooting is completed and logged, to the delivery of the CRU or arrival of a Service Technician and part at the Customer’s location for repair.
Committed Repair 6 hours: The time period between the service request registration in Lenovo’s call management system and the restoration of the product to conformance with its specification by a Service Technician. 

The following Lenovo warranty service upgrades are available:

  • Warranty and maintenance service upgrades:
    • Three, four, or five years of 9x5 or 24x7 service coverage
    • Parts delivered or technician installed parts from next business day to 4 or 2 hours
    • Committed repair service
    • Warranty extension of up to 5 years
    • Post warranty extensions
  • Committed Repair Service

    Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.

    • Priority handling to meet defined time frames to restore the failing machine to good working condition
    • 24x7x6 committed repair: Service performed 24 hours per day, 7 days per week, within 6 hours
  • YourDrive YourData

    Lenovo’s YourDrive YourData service is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Lenovo warranty upgrades and extensions.

  • Microcode Support

    Keeping microcode current helps prevent hardware failures and security exposure. There are two levels of service: analysis of the installed base and analysis and update where required. Offerings vary by country and can be bundled with other warranty upgrades and extensions.

  • Enterprise Software Support

    Lenovo Enterprise Server Software Support can help you troubleshoot your entire server software stack. Choose support for server operating systems from Microsoft, Red Hat, SUSE, and VMware; Microsoft server applications; or both operating systems and applications. Support staff can help answer troubleshooting and diagnostic questions, address product compatibility and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

    In addition, you can access hardware “how to” support for ThinkSystem servers. Staff can help resolve hardware problems not covered under warranty, refer you to the right documentation and publications, provide corrective service information for known defects, and transfer you to a hardware support call center if needed.

  • Hardware Installation Services

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities. Your new systems will be configured and ready for your software installation.

Regulatory compliance

The SR950 server conforms to the following regulations:

  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 6, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • IEC 62368-1 2014(CB Certificate and CB Test Report)
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
  • China CCC GB4943.1, GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1 CNS15663
  • Korea KN32, Class A; KN35
  • Russia, Belorussia and Kazakhstan, TR CU 020/2011 (for EMC) and TR CU 004/2011 (for safety)
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55032 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
  • CISPR 32, Class A
  • TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000)
  • RoHS Directive
  • Energy Star 2.1
  • ErP lot3
  • JESL

 

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

The following table lists the standard models of the D1212 and D1224 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.

Table 58. D1212 and D1224 standard models
Part number Description
LFF models
4587A11* D1212 LFF Chassis, Dual 3-port ESMs (US English documentation)
4587A1C^ D1212 LFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)
4587A1J** D1212 LFF Chassis, Dual 3-port ESMs (Japanese documentation)
SFF models
4587A31* D1224 SFF Chassis, Dual 3-port ESMs (US English documentation)
4587A3C^ D1224 SFF Chassis, Dual 3-port ESMs (Simplified Chinese documentation)
4587A3J** D1224 SFF Chassis, Dual 3-port ESMs (Japanese documentation)

* Available worldwide (except China and Japan)
^ Available only in China
** Available only in Japan

The following table lists the TopSeller models of the D1212 and D1224 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion.

Table 59. D1212 and D1224 TopSeller models
Part number Description
Brazil and Latin America - LFF models
4587EAU D1212 LFF Chassis, Dual 3-port ESMs, 4x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EBU D1212 LFF Chassis, Dual 3-port ESMs, 4x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587ECU D1212 LFF Chassis, Dual 3-port ESMs, 4x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587EDU D1212 LFF Chassis, Dual 3-port ESMs, 4x 8TB 3.5" HDDs, 4x 0.5m SAS cables
4587EEU D1212 LFF Chassis, Dual 3-port ESMs, 8x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EFU D1212 LFF Chassis, Dual 3-port ESMs, 8x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587EGU D1212 LFF Chassis, Dual 3-port ESMs, 8x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587EHU D1212 LFF Chassis, Dual 3-port ESMs, 8x 8TB 3.5" HDDs, 4x 0.5m SAS cables
4587EIU D1212 LFF Chassis, Dual 3-port ESMs, 12x 2TB 3.5" HDDs, 4x 0.5m SAS cables
4587EJU D1212 LFF Chassis, Dual 3-port ESMs, 12x 4TB 3.5" HDDs, 4x 0.5m SAS cables
4587EKU D1212 LFF Chassis, Dual 3-port ESMs, 12x 6TB 3.5" HDDs, 4x 0.5m SAS cables
4587ELU D1212 LFF Chassis, Dual 3-port ESMs, 12x 8TB 3.5" HDDs, 4x 0.5m SAS cables
Brazil and Latin America - SFF models
4587E6U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 0.5m SAS cables
4587E2U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables
4587E4U D1224 SFF Chassis, Dual 3-port ESMs, 9x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables
4587E5U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 1x 0.5m SAS cable
4587E1U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables
4587E3U D1224 SFF Chassis, Dual 3-port ESMs, 18x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables

For details about supported drives and cables for the Lenovo Storage D1212 and D1224, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0512

The following table lists the standard models of the D3284 12 Gbps SAS external high density drive enclosures offered by Lenovo.

Table 60. D3284 standard models
Description Part number
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 641311F
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 641312F
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 641313F
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 641314F

The following table lists the TopSeller models of the D3284 12 Gbps SAS external high density drive enclosures offered by Lenovo.

Table 61. D3284 TopSeller models
Description Part number
Lenovo Storage D3284 High Density Expansion Enclosure 6413E5F
Lenovo Storage D3284 4TB x 42 HD Expansion Enclosure 6413E1H
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 6413E1F
Lenovo Storage D3284 6TB x 42 HD Expansion Enclosure 6413E2H
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 6413E2F
Lenovo Storage D3284 8TB x 42 HD Expansion Enclosure 6413E3H
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 6413E3F
Lenovo Storage D3284 10TB x 42 HD Expansion Enclosure 6413E4H
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 6413E4F

For details about supported drives, adapters, and cables for the Lenovo Storage D3284, see the Lenovo Press Product Guide:
http://lenovopress.com/lp0513

External storage systems

The following table lists the external storage systems that are currently offered by Lenovo.

Note: Information provided in this section is for ordering reference purposes only. End-to-end storage configuration support must be verified through the interoperability matrix for a particular storage system that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 62. External storage systems
Description Part number
Lenovo ThinkSystem DS Series Storage (SAS connectivity)
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (US English documentation) 4599A41*
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Simplified Chinese documentation) 4599A4C^
Lenovo ThinkSystem DS2200 LFF SAS Dual Controller Unit (Japanese documentation) 4599A4J**
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (US English documentation) 4599A21*
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Simplified Chinese documentation) 4599A2C^
Lenovo ThinkSystem DS2200 SFF SAS Dual Controller Unit (Japanese documentation) 4599A2J**
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (US English documentation) 4617A41*
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Simplified Chinese documentation) 4617A4C^
Lenovo ThinkSystem DS4200 LFF SAS Dual Controller Unit (Japanese documentation) 4617A4J**
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (US English documentation) 4617A21*
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Simplified Chinese documentation) 4617A2C^
Lenovo ThinkSystem DS4200 SFF SAS Dual Controller Unit (Japanese documentation) 4617A2J**
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (US English documentation) 4619A21*
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Simplified Chinese documentation) 4619A2C^
Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit (Japanese documentation) 4619A2J**
Lenovo ThinkSystem DS Series Storage (iSCSI or FC connectivity)
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (US English documentation) 4599A31*
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4599A3C^
Lenovo ThinkSystem DS2200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4599A3J**
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (US English documentation) 4599A11*
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4599A1C^
Lenovo ThinkSystem DS2200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4599A1J**
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (US English documentation) 4617A31*
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4617A3C^
Lenovo ThinkSystem DS4200 LFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4617A3J**
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (US English documentation) 4617A11*
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4617A1C^
Lenovo ThinkSystem DS4200 SFF FC/iSCSI Dual Controller Unit (Japanese documentation) 4617A1J**
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (US English documentation) 4619A11*
Lenovo ThinkSystem DS6200 SFF FC/iSCSI Dual Controller Unit (Simplified Chinese documentation) 4619A1C^
Lenovo Storage V Series (SAS [except V7000/V7000F], iSCSI, or FC connectivity)
Lenovo Storage V3700 V2 LFF Control Enclosure 6535C1D
Lenovo Storage V3700 V2 LFF Control Enclosure (TopSeller) 6535EC1
Lenovo Storage V3700 V2 SFF Control Enclosure 6535C2D
Lenovo Storage V3700 V2 SFF Control Enclosure (TopSeller) 6535EC2
Lenovo Storage V3700 V2 XP LFF Control Enclosure 6535C3D
Lenovo Storage V3700 V2 XP LFF Control Enclosure (TopSeller) 6535EC3
Lenovo Storage V3700 V2 XP SFF Control Enclosure 6535C4D
Lenovo Storage V3700 V2 XP SFF Control Enclosure (TopSeller) 6535EC4
Lenovo Storage V5030 LFF Control Enclosure 3Yr S&S 6536C12
Lenovo Storage V5030 LFF Control Enclosure 5Yr S&S 6536C32
Lenovo Storage V5030 SFF Control Enclosure 3Yr S&S 6536C22
Lenovo Storage V5030 SFF Control Enclosure 5Yr S&S 6536C42
Lenovo Storage V5030F SFF Control Enclosure 3Yr S&S 6536B1F
Lenovo Storage V5030F SFF Control Enclosure 5Yr S&S 6536B2F
Lenovo Storage V7000 SFF Control Enclosure 3Yr S&S PRC 6538R11^
Lenovo Storage V7000 SFF Control Enclosure 5Yr S&S PRC 6538R21^
Lenovo Storage V7000F SFF Control Enclosure 3Yr S&S PRC 6538R1G^
Lenovo Storage V7000F SFF Control Enclosure 5Yr S&S PRC 6538R2G^
IBM Storwize for Lenovo (SAS [except V7000], iSCSI, or FC connectivity)
IBM Storwize V3500 3.5-inch Dual Control Storage Controller Unit 6096CU2^
IBM Storwize V3500 2.5-inch Dual Control Storage Controller Unit 6096CU3^
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA 6195C32†
IBM Storwize V7000 SFF Control Enclosure, 3YR SWMA, LA 6195C3L‡
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA 6195C52†
IBM Storwize V7000 SFF Control Enclosure, 5YR SWMA, LA 6195C5L‡

* Available worldwide (except China and Japan).
^ Available only in China.
** Available only in Japan.
† Available worldwide except Latin America.
‡ Available only in Latin America.

For more information, see the list of Product Guides in the following categories:

External backup units

The server supports both USB-attached RDX backup units and SAS-attached tape drives.

The following table lists the supported external SAS tape backup options.

Tip: Verify the end-to-end support of an IBM tape backup solution through the IBM System Storage Interoperation Center (SSIC): http://www.ibm.com/systems/support/storage/ssic

Table 63. External SAS backup options
Part number Description
External SAS tape backup drives
6160S5E IBM TS2250 Tape Drive Model H5S
6160S6E IBM TS2260 Tape Drive Model H6S
6160S7E IBM TS2270 Tape Drive Model H7S
External SAS tape backup autoloaders
6171S5R IBM TS2900 Tape Autoloader w/LTO5 HH SAS
6171S6R IBM TS2900 Tape Autoloader w/LTO6 HH SAS
6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS
External tape backup libraries
61732UL IBM TS3100 Tape Library Model L2U
61734UL IBM TS3200 Tape Library Model L4U
SAS backup drives for TS3100 and TS3200 Tape Libraries
00NA109 6173 LTO Ultrium 5 SAS Drive Sled
00NA111 6173 LTO Ultrium 5 Half High SAS Drive Sled
00NA117 6173 LTO Ultrium 6 Half High SAS Drive Sled
00WF767 6173 LTO Ultrium 7 Half High SAS Drive Sled

For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup

The following table lists the external RDX backup options available.

Table 64. External RDX dock and cartridges
Part number Feature code Description
External RDX docks
4T27A10725 B32R ThinkSystem RDX External USB 3.0 Dock (No cartridge included with the drive)
Cartridges
7TP7A01601 AVF8 ThinkSystem RDX 500GB Cartridge
7TP7A01602 AVF1 ThinkSystem RDX 1TB Cartridge
7TP7A01603 AVF0 ThinkSystem RDX 2TB Cartridge
7TP7A04318 AXD1 ThinkSystem RDX 4TB Cartridge

For more information, see the Lenovo RDX USB 3.0 Disk Backup Solution product guide:
https://lenovopress.com/tips0894-rdx-usb-30

Top-of-rack Ethernet switches

The following table lists the Ethernet LAN switches that are offered by Lenovo.

Table 65. Ethernet LAN switches
Part number Description
1 Gb Ethernet switches
7165H1X Juniper EX2300-C PoE Switch
7165H2X Juniper EX2300-24p PoE Switch
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159BR6 Lenovo RackSwitch G8124E (Rear to Front)
7159G64 Lenovo RackSwitch G8264 (Rear to Front)
7159DRX Lenovo RackSwitch G8264CS (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
25 Gb Ethernet switches
7159E1X Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)
40 Gb Ethernet switches
7159BRX Lenovo RackSwitch G8332 (Rear to Front)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)

For more information, see the list of Product Guides in the following switch categories:

Fibre Channel SAN switches

The following table lists the Fibre Channel SAN switches that are offered by Lenovo and can be used with this system.

Table 66. Fibre Channel SAN switches
Part number Description
8 Gb FC
3873AR3 Lenovo B300, 8 ports activated, 8x 8Gb SWL SFPs, 1 PS, Rail Kit
3873AR4 Lenovo B6505, 12 ports activated, 12x 8Gb SWL SFPs, 1 PS, Rail Kit
3873BR2 Lenovo B6510, 24 ports activated, 24x 8Gb SWL SFPs, 2 PS, Rail Kit
16 Gb FC
6559D2Y Lenovo ThinkSystem DB610S, 8 ports activated, 8x 16Gb SWL SFPs, 1 PS, Rail Kit
6559D1Y Lenovo ThinkSystem DB610S, 24 ports activated, 24x 16Gb SWL SFP, Enterprise SW, 1 PS, Rail Kit
3873AR5 Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit
3873BR3 Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit
32 Gb FC
6559D3Y Lenovo ThinkSystem DB610S, 8 ports activated, 1 PS, Rail Kit
6415G3A Lenovo ThinkSystem DB620S, 24 ports activated, No SFPs, 2 PS, Rail Kit
6415G11 Lenovo ThinkSystem DB620S, 24 Ports Activated, 24x 32Gb SWL SFPs, 2 PS, Rail Kit
6415G2A Lenovo ThinkSystem DB620S, 48 Ports Activated, 48x 32Gb SWL SFPs, 2 PS, Rail Kit
6684B2A Lenovo ThinkSystem DB400D 32Gb FC Director, up to 192 ports, 8U, Enterprise SW
6682B1A Lenovo ThinkSystem DB800D 32Gb FC Director, up to 384 ports, 14U, Enterprise SW

For more information, see the list of Product Guides in the Rack SAN Switches category:
http://lenovopress.com/storage/switches/rack?rt=product-guide

Uninterruptible power supply units

The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo.

Table 67. Uninterruptible power supply units
Part number Description
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)

† Only available in China and countries in the Asia Pacific region.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 68. Power distribution units
Part number Description
0U Basic PDUs
00YJ776 0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord
00YJ777 0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord
00YJ778 0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord
00YJ779 0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord
Switched and Monitored PDUs
00YJ780 0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord
00YJ781 0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord
00YJ782 0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord
00YJ783 0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord
46M4002 1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)
46M4003 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
46M4004 1U 12 C13 Switched and Monitored DPI PDU (without line cord)
46M4005 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71762NX Ultra Density Enterprise C19/C13 PDU Module (without line cord)
71763NU Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 DPI C13 Enterprise PDU+ (without line cord)
39Y8941 DPI Single Phase C13 Enterprise PDU (without line cord)
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 DPI Single Phase C19 Enterprise PDU (without line cord)
39Y8923 DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord
Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord
39Y8939 DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord
39Y8934 DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8940 DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8935 DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 DPI 100-127V PDU with Fixed NEMA L5-15P line cord
Line cords for PDUs that ship without a line cord
40K9611 DPI 32a Line Cord (IEC 309 3P+N+G)
40K9612 DPI 32a Line Cord (IEC 309 P+N+G)
40K9613 DPI 63a Cord (IEC 309 P+N+G)
40K9614 DPI 30a Line Cord (NEMA L6-30P)
40K9615 DPI 60a Cord (IEC 309 2P+G)
40K9617 DPI Australian/NZ 3112 Line Cord
40K9618 DPI  Korean 8305 Line Cord

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

The racks supported by the server are listed in the following table.

Table 69. Rack cabinets
Part number Description Maximum
supported
Rack cabinets currently available
9308-4EX 42U Enterprise Expansion Rack 10
9308-4PX 42U Enterprise Rack 10
9360-4PX 42U 1200mm Deep Dynamic Rack 10
9361-4PX 42U 1200mm Deep Static Rack 10
9363-4PX 42U 1100mm Dynamic Rack 10
9363-4EX 42U 1100mm Dynamic Expansion Rack 10
Withdrawn rack cabinets
9360-4EX 42U 1200mm Deep Dynamic Expansion Rack 10
9361-4EX 42U 1200mm Deep Static Expansion Rack 10
9362-4PX 47U 1200mm Deep Static Rack 11
9362-4EX 47U 1200mm Deep Static Expansion Rack 11
9363-4CX PureFlex System 42U Rack 10
9363-4DX PureFlex System 42U Expansion Rack 10

For information about these racks, see the Lenovo Rack Cabinet Reference:
https://lenovopress.com/lp0658-lenovo-rack-cabinet-reference

KVM console options

The following table lists the supported KVM consoles, keyboards, and KVM switches.

 
Table 70. Console keyboards
Part number Description
Consoles
17238BX 1U 18.5" Standard Console (without keyboard)
Console keyboards
7ZB7A05469 ThinkSystem Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portugese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard w/ Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2
ThinkSystem Digital and Analog KVM Console switches and cables
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
GCM and LCM Console switches and cables
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option (4 Pack UCO)
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

http://www.lenovofs.com