Critical "SIM removed on enclosure" messages appear in MSM 오류 해결방법

엔지니어-FIXER 2011. 8. 30. 09:38

EXP3000을연결하고 MSM에서 이상한 메시지가 발생하면 해결방법입니다

리테인팁 H187618 를 검색하시면 됩니다.



This message is expected behavior because a second Environmental Services Module is not installed in the EXP3000. Open the LSI MegaRAID Storage Manager Application and perform the following steps to remove the Critical message from appearing:

  1. From the main menu, select Tools.
  2. Select Configure alerts.
  3. Select Change Individual Events.
  4. Select Alert Delivery Method.
  5. Select Event ID 176 SIM removed on enclosure that has a Severity of "Critical."
  6. In the Alert Delivery Methods section, remove the check from all options.
  7. Press OK twice to exit the Tools Menu.


간단한 해결방법입니다.