My Retain Tip/X Series

processor 1 is operating in a Degraded 메시지 발생시

엔지니어-FIXER 2014. 9. 14. 01:30

Chassis Event Log 03/27/2013 00:40:29 806f0a070301ffff PLAT0038 processor 1 is operating in a Degraded State. Degraded/Warning
Chassis Event Log 03/27/2013 00:40:33 4000007f00000000 IMM0127 Power cap throttling occurred. Information
Chassis Event Log 03/27/2013 00:40:40 816f0a070301ffff PLAT0039 The Processor processor 1 is no longer operating in a Degraded State. Information

 

위 메시지 발생시 조치방법

 

해당 서버는

 

  • System x3300 M4, type 7382, any model
  • System x3500 M4, type 7383, any model
  • System x3550 M4, type 7914, any model
  • System x3630 M4, type 7158, any model
  • System x3650 M4, type 7915, any model
  •  

     

    위 모델들이 해당하며

     

    파워 문제라고 나와있네요

     

    This behavior was corrected in the new Acbel Power supply. The Field Replacement Unit (FRU) number is #94Y8110.

     

    이게 해결법이네요

     

    링크 : http://www-947.ibm.com/support/entry/portal/docdisplay?lndocid=migr-5093598