BLOG main image
분류 전체보기 (781)
LENOVO (19)
HP (3)
DELL (7)
IBM (32)
My Retain Tip (697)
자료실 (0)
Firmware (5)
기타서버관련소식 (5)
IBM Server Picture (3)
STUDY (2)
설정세팅 (0)
Visitors up to today!
Today hit, Yesterday hit
daisy rss
tistory 티스토리 가입하기!
2010. 10. 9. 10:26
Notice!!
IBM
본 블로그의 모든내용은 ibm.com에 있는 내용이며 본 블로그의 내용은 증빙내용으로는 활용 불가능합니다
주의! 모든 방문자는 공지를 반드시 읽어본 후 글을 읽으시기 바랍니다.:*필독공지*

딴지 거실분들은 절대 읽지 마시고 100% 정확한 정보가 있는 ibm.com 에서 확인하시기 바랍니다.
Single controller DS3000 showing controller B errors - IBM System Storage DS3200 (Type 1726-21X), DS3400 (Type 1726-41X)

두가지 방법이 있습니다.
펌웨어 먼저 적용해주고 해야합니다.


RETAIN tip: H19631

Symptom

A single controller System Storage DS3200 (Type 1726-21X), a single controller System Storage DS3300 (Type 1726-31X), or a single controller System Storage DS3400 (Type 1726-41X), may show error messages related to controller B or loss of path redundancy.

The following messages are generally what will be seen in the major event log:

  7/26/07 3:21:51 PM 83 2605 Info 0/0/0 Ctr: A Start-of-day routine completed

7/26/07 3:21:45 PM 82 2112 Info 0/0/0 Controller enclosure Controller cache battery is fully charged

7/26/07 3:21:45 PM 81 281D Crit 0/0/0 Enclosure 85, Slot 2 Temperature sensor removed

7/26/07 3:21:45 PM 80 280A Crit 0/0/0 Enclosure 85 Controller enclosure component removed

7/26/07 3:21:45 PM 79 2829 Crit 0/0/0 Ctr: A Controller redundancy lost

7/26/07 3:21:45 PM 78 3101 Info 6/e0/20 Ctr: A ASC/ASCQ: E020 FW: 06173100 SN: SF71600777 replacement part number:09

7/26/07 3:21:15 PM 77 2606 Info 0/0/0 Ctr: A Start-of-day routine begun 7/26/07 3:19:29 PM 76 280B Crit 0/0/0 Enclosure 85, Slot 2 Controller enclosure component failed

7/26/07 3:19:29 PM 75 280B Crit 0/0/0 Enclosure 85, Slot 2 Controller enclosure component failed

In recovery guru, the following entries will most likely be seen:

  Failure Entry 1: NON_FRU_REMOVED_BATTERY Failure Entry 2: REMOVED_POWER_FAN_CANISTER Failure Entry 3: NO_REDUNDANCY_TRAY Failure Entry 4: DEGRADED_DRIVE_PATH

Affected configurations

The system may be any of the following IBM servers:

  • System Storage DS3200, type 1726, model 21X
  • System Storage DS3300, type 1726, model 31X
  • System Storage DS3400, type 1726, model 41X

This tip is not option specific.

This tip is not software specific.

Solution

OPTION 1:

Install the single-controller NVSRAM on controller A. See "Downloading controller or NVSRAM" in the System Storage DS3000 Storage Manager Installation and Support Guide for information about how to download the NVSRAM software. Obtain the latest single-controller NVSRAM software from the following URL:

Use the script editor to execute the command. To use this option, open Storage Manager. Right click on the System Storage DS3200, DS3300 or DS3400 in the Enterprise Management window. Select Execute Script from the menu that appears. This will open the script editor window. Enter the command as follows in the top half of the of the script editor window:

  set storageSubsystem redundancyMode=simplex;

Then, click on the Tools menu and select Execute Only.

OPTION 2:

Using the command-line interface options, enter the following command to change controller A from duplex (dual-controller) mode to simplex (single-controller) mode:

  set storageSubsystem redundancyMode=simplex

Use the SMCli utility to execute the command. This option utilizes your operating system's command line to connect to the system via its IP address and execute the command. Type the following command at a command prompt in your operating system:

  Smcli ctlr_A_IP_address -c "set storageSubsystem redundancyMode=simplex;"

Be sure to replace ctlr_A_IP_address with the actual IP address of the management port on the A controller.


About
IBM 최신서버에 관련된 경험과 지식을 공유하는 블로그이며 블로그에 처음오신분은 *필독공지*를 꼭 먼저 읽어보시기 바랍니다.