H19631: Single controller DS3000 showing controller B errors - IBM System Storage DS3200 (Type 1726-21X), DS3400 (Type 1726-41X)
컨트롤러는 하나를 쓰는데 다른 컨트롤러에서 오류가 계속 리포트 될때 해결방법입니다.
증상
A single controller System Storage DS3200 (Type 1726-21X), a single controller System Storage DS3300 (Type 1726-31X), or a single controller System Storage DS3400 (Type 1726-41X), may show error messages related to controller B or loss of path redundancy.
The following messages are generally what will be seen in the major event log:
7/26/07 3:21:51 PM 83 2605 Info 0/0/0 Ctr: A Start-of-day routine completed 7/26/07 3:21:45 PM 82 2112 Info 0/0/0 Controller enclosure Controller cache battery is fully charged 7/26/07 3:21:45 PM 81 281D Crit 0/0/0 Enclosure 85, Slot 2 Temperature sensor removed 7/26/07 3:21:45 PM 80 280A Crit 0/0/0 Enclosure 85 Controller enclosure component removed 7/26/07 3:21:45 PM 79 2829 Crit 0/0/0 Ctr: A Controller redundancy lost 7/26/07 3:21:45 PM 78 3101 Info 6/e0/20 Ctr: A ASC/ASCQ: E020 FW: 06173100 SN: SF71600777 replacement part number:09 7/26/07 3:21:15 PM 77 2606 Info 0/0/0 Ctr: A Start-of-day routine begun 7/26/07 3:19:29 PM 76 280B Crit 0/0/0 Enclosure 85, Slot 2 Controller enclosure component failed 7/26/07 3:19:29 PM 75 280B Crit 0/0/0 Enclosure 85, Slot 2 Controller enclosure component failed |
In recovery guru, the following entries will most likely be seen:
Failure Entry 1: NON_FRU_REMOVED_BATTERY Failure Entry 2: REMOVED_POWER_FAN_CANISTER Failure Entry 3: NO_REDUNDANCY_TRAY Failure Entry 4: DEGRADED_DRIVE_PATH |
위 메시지가 계속 나옵니다.
영향을 받는 장비들
위 장비들은 싱글 전용장비입니다.
해결방법
OPTION 1:
Install the single-controller NVSRAM on controller A. See "Downloading controller or NVSRAM" in the System Storage DS3000 Storage Manager Installation and Support Guide for information about how to download the NVSRAM software. Obtain the latest single-controller NVSRAM software from the following URL:
Use the script editor to execute the command. To use this option, open Storage Manager. Right click on the System Storage DS3200, DS3300 or DS3400 in the Enterprise Management window. Select Execute Script from the menu that appears. This will open the script editor window. Enter the command as follows in the top half of the of the script editor window:
set storageSubsystem redundancyMode=simplex; |
Then, click on the Tools menu and select Execute Only.
OPTION 2:
Using the command-line interface options, enter the following command to change controller A from duplex (dual-controller) mode to simplex (single-controller) mode:
set storageSubsystem redundancyMode=simplex |
Use the SMCli utility to execute the command. This option utilizes your operating system's command line to connect to the system via its IP address and execute the command. Type the following command at a command prompt in your operating system:
Smcli ctlr_A_IP_address -c "set storageSubsystem redundancyMode=simplex;" |
Be sure to replace ctlr_A_IP_address with the actual IP address of the management port on the A controller.
명령어를 입력후 리부팅 해주면 됩니다.
간단히 가능합니다. 듀얼 모드로 되어있어서 그렇습니다.
'My Retain Tip > Storage DS' 카테고리의 다른 글
Disk Systems, FAStT200 펌웨어 스토리지 메니져 (0) | 2010.09.15 |
---|---|
IBM 스토리지 1726 비롯 DS3000대 시리즈는 배터리 교체시 소모품으로 유상입니다. (0) | 2010.09.08 |
IBM DS serise Firmware 6.x -> 7.x upgrade시 주의사항 (0) | 2010.09.05 |
IBM 스토리지 DS3400 1726-HC4 싱글->듀얼 컨트롤러 장착시 MES (0) | 2010.09.03 |
IBM DS5020 스토리지 메니져 데모. (0) | 2010.08.31 |