2011. 4. 30. 11:39
Notice!!
IBM
본 블로그의 모든내용은 ibm.com에 있는 내용이며 본 블로그의 내용은 증빙내용으로는 활용 불가능합니다
주의! 모든 방문자는 공지를 반드시 읽어본 후 글을 읽으시기 바랍니다.:*필독공지*

딴지 거실분들은 절대 읽지 마시고 100% 정확한 정보가 있는 ibm.com 에서 확인하시기 바랍니다.
IMM은 미디어키를 구매해야지 리모트 컨트롤이 됩니다
기본은 없으니 옵션으로 구매하시고
구매해서 접속하려고 할때 안나오면 아래 방법으로 하세요

Source

RETAIN tip: H196657

Symptom

When using Microsoft Internet Explorer (IE) 7 or 8 with an Integrated Management Module (IMM), the remote control window does not open, Java is not started, and there is no warning that a pop-up was blocked.

Steps to recreate the issue:

  1. Click Remote control.

  2. Click "Start Remote Control in Single User Mode" or "Start Remote Control in Multi-User Mode."

Affected configurations

The system may be any of the following IBM servers:

  • System x3200 M3, type 7327, any model
  • System x3200 M3, type 7328, any model
  • System x3250 M3, type 4251, any model
  • System x3250 M3, type 4252, any model
  • System x3250 M3, type 4261, any model
  • System x3400 M2, type 7836, any model
  • System x3400 M2, type 7837, any model
  • System x3500 M2, type 7839, any model
  • System x3550 M2, type 4198, any model
  • System x3550 M2, type 7946, any model
  • System x3650 M2, type 4199, any model
  • System x3650 M2, type 7947, any model

This tip is not software specific.
This tip is not option specific.

Workaround

IE advanced security settings are blocking the Java application from starting.

Workaround 1:

  • In the Remote control Window, hold the Ctrl key and click "Start Remote Control in Single User Mode" or "Start Remote Control in Multi-User Mode."

Workaround 2:

Add the IMM Internet Protocol (IP) address to the local intranet secure sites:

  1. From IE, select Tools --> Internet Options --> Security tab --> Local intranet --> "Sites" button --> "Advanced" button.

  2. Add the IP address of the IMM: http://192.168.70.125 (at default)

  3. Clear the "Require server verification (https:) for all sites in this zone" check box.

  4. Select Close.

  5. Select OK.

  6. Select OK.

  7. Press F5 to refresh IE.

  8. Click Remote control.

  9. Click "Start Remote Control in Single User Mode" or "Start Remote Control in Multi-User Mode."

The Java window will start with the remote control session and the Virtual Media Session. Java is required for this to work. Refer to the IMM User's Guide for more details:

http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5079770

Workaround 3:

  • Use Firefox or another Web browser.