2010. 9. 26. 10:59
MegaRAID 8480 SAS Controller Firmware 은 반드시 펌웨어가 최신으로 올라가야합니다
그렇지 않으면 스토리지 끊김 현상 발생합니다
Critical 이니 반드시 업데이트 하세요!
그렇지 않으면 스토리지 끊김 현상 발생합니다
Critical 이니 반드시 업데이트 하세요!
2010.4.8일자 업데이트 입니다.
LSI MegaRAID 8480 SAS Controller Firmware Update
NOTE TO SERVICE - Reference RETAIN #N/A
Version 7.0.1-0074 - Critical
------------------
Contains:
Firmware Image: 1.12.270-0718
MPT Firmware: 01.18.170.00-IT
Boot Block: R2.3.15
BIOS: MT33
Web BIOS: 1.1-33g-e_11-Rel
Control-R: 1.04-019A
Preboot CLI: 01.00-011
- Fixed issue where the iBBU recalibration does not finish and goes into a
battery charge/discharge loop
- Addressed issue where the firwmare could generate a fatal firmware
- Fixed controller hang when the a single inconsistency is found on RAID 5.
- Fixed firmware problem where flushing disk cache in some shutdown scenarios
does not occur correctly
- Addressed a problem where a continuous Media Error (CME) will cause a firmware
crash
- Fixed a problem where the selection of any physical drive will fail if global
hot spare is created out of smaller PD.
- Corrected a issue where a SMART error is still reported in 24 hours, even after replacing with good disk
Version 7.0.1-0064 - Critical
------------------
RETAIN tip H194224, H194505, H194171 and H193699
Contains:
Firmware Image: 1.12.220-0560
MPT Firmware: 01.18.79.00-IT
Boot Block: R2.3.15
BIOS: MT33
Web BIOS: 1.1-33g-e_11-Rel
Control-R: 1.04-019A
Preboot CLI: 01.00-011
- Fixed Data integrity issue with multi-row write.
- Fixed issue where the Operating system is not found when an error occurs
in DDF anchor.
- Fixed data integrity issue where commands were lost during heavy I/O.
- Fixed issue where the firmware incorrectly sets battery status as missing.
- Fixed media errors which transpired with data under runs.
- Fixed issue where firmware was not getting event logs with wrapped events.
- Fixed issue when single drive pull causes all drives on quad to fail.
- Fixed regenerate parity after hitting double media error.
- Incorporated Unicoi NVRAM checksum fix
- Modified the Gas Gauge temperature offset to 0.7 for all LiON batteries
- Fixed defect when inconsistency found during patrol read when physical disk
status are changed from online to missing.
- Fixed PCI SERR on boot in x3650 with RSAII coexistence.
- Changed Vivaldi drive size reporting from MB to GB.
'My Retain Tip > Storage DS' 카테고리의 다른 글
이것이 바로 Multi Defunct DISK ERROR 의 현상 (0) | 2010.09.28 |
---|---|
DS3000 시리즈 설치시 듀얼컨트롤러 고장증상? (0) | 2010.09.27 |
Nseries 권한 설정 후 저장 방법 (0) | 2010.09.19 |
Disk Systems, FAStT200 펌웨어 스토리지 메니져 (0) | 2010.09.15 |
IBM 스토리지 1726 비롯 DS3000대 시리즈는 배터리 교체시 소모품으로 유상입니다. (0) | 2010.09.08 |