MegaRAID 8480 SAS Controller Firmware 은 반드시 펌웨어가 최신으로 올라가야합니다
그렇지 않으면 스토리지 끊김 현상 발생합니다
Critical 이니 반드시 업데이트 하세요!

2010.4.8일자 업데이트 입니다.




LSI MegaRAID 8480 SAS Controller Firmware Update

NOTE TO SERVICE - Reference RETAIN #N/A

Version 7.0.1-0074 - Critical
------------------
Contains:
     Firmware Image: 1.12.270-0718
     MPT Firmware: 01.18.170.00-IT
     Boot Block: R2.3.15
     BIOS: MT33
     Web BIOS: 1.1-33g-e_11-Rel
     Control-R: 1.04-019A
     Preboot CLI: 01.00-011

- Fixed issue where the iBBU recalibration does not finish and goes into a
   battery charge/discharge loop
- Addressed issue where the firwmare could generate a fatal firmware
- Fixed controller hang when the a single inconsistency is found on RAID 5.
- Fixed firmware problem where  flushing disk cache in some shutdown scenarios
   does not occur correctly
- Addressed a problem where a continuous Media Error (CME) will cause a firmware
   crash
- Fixed a problem where the selection of any physical drive will fail if global
   hot spare is created out of smaller PD.
- Corrected a issue where a SMART error is still reported in 24 hours, even after       replacing with good disk

Version 7.0.1-0064 - Critical
------------------
RETAIN tip H194224, H194505, H194171 and H193699
Contains:
     Firmware Image: 1.12.220-0560
     MPT Firmware: 01.18.79.00-IT
     Boot Block: R2.3.15
     BIOS: MT33
     Web BIOS: 1.1-33g-e_11-Rel
     Control-R: 1.04-019A
     Preboot CLI: 01.00-011

- Fixed Data integrity issue with multi-row write.
- Fixed issue where the Operating system is not found when an error occurs
   in DDF anchor.
- Fixed data integrity issue where commands were lost during heavy I/O.
- Fixed issue where the firmware incorrectly sets battery status as missing.
- Fixed media errors which transpired with data under runs.
- Fixed issue where firmware was not getting event logs with wrapped events.
- Fixed issue when single drive pull causes all drives on quad to fail.
- Fixed regenerate parity after hitting double media error.
- Incorporated Unicoi NVRAM checksum fix
- Modified the Gas Gauge temperature offset to 0.7 for all LiON batteries
- Fixed defect when inconsistency found during patrol read when physical disk
   status are changed from online to missing.
- Fixed PCI SERR on boot in x3650 with RSAII coexistence.
- Changed Vivaldi drive size reporting from MB to GB.