2011. 8. 4. 11:16
리테인 참고해서
확인 해보세요
RETAIN tip: H196657
위 리테인 참고하면 해결법있습니다
아예 시작이 안되면 익스플로어문제가 많죠
Workaround 1:
- In the Remote control Window, hold the Ctrl key and click "Start Remote Control in Single User Mode" or "Start Remote Control in Multi-User Mode."
Workaround 2:
Add the IMM Internet Protocol (IP) address to the local intranet secure sites:
- From IE, select Tools --> Internet Options --> Security tab --> Local intranet --> "Sites" button --> "Advanced" button.
- Add the IP address of the IMM: http://192.168.70.125 (at default)
- Clear the "Require server verification (https:) for all sites in this zone" check box.
- Select Close.
- Select OK.
- Select OK.
- Press F5 to refresh IE.
- Click Remote control.
- Click "Start Remote Control in Single User Mode" or "Start Remote Control in Multi-User Mode."
The Java window will start with the remote control session and the Virtual Media Session. Java is required for this to work. Refer to the IMM User's Guide for more details:
http://www.ibm.com/support/docview.wss?uid=psg1MIGR-5079770
Workaround 3:
- Use Firefox or another Web browser.