Processor x is in a degraded state
M5 장비 위 메시지에 대한 대응방법
펌웨어 및 설정 확인
CPU관련 설정이 중요함
Solution
This behavior was corrected in system IMM firmware Version 3.50, Build ID: TCOO24A and UEFI firmware Version 2.21, Build ID: TCE126Q.
The file is or will be available by selecting the appropriate Product Group, type of System, Product name, Product machine type, and Operating system on IBM Support's Fix Central web page, at the following URL:
http://www.ibm.com/support/fixcentral/
Workaround
The behavior may be improved if the following system settings are used in system UEFI setup:
OperatingModes.ChooseOperatingMode=Custom Mode Processors.C-States=Disable Processors.EnergyEfficientTurbo=Disable Processors.UncoreFrequencyScaling=Enable Power.ActiveEnergyManager=Capping Disable Power.PlatformControlledType=Maximum Performance
Note: Disabling C-states will increase CPU idle power but will gain in maximum CPU performance.