EXP3000을연결하고 MSM에서 이상한 메시지가 발생하면 해결방법입니다
리테인팁 H187618 를 검색하시면 됩니다.
This message is expected behavior because a second Environmental Services Module is not installed in the EXP3000. Open the LSI MegaRAID Storage Manager Application and perform the following steps to remove the Critical message from appearing:
- From the main menu, select Tools.
- Select Configure alerts.
- Select Change Individual Events.
- Select Alert Delivery Method.
- Select Event ID 176 SIM removed on enclosure that has a Severity of "Critical."
- In the Alert Delivery Methods section, remove the check from all options.
- Press OK twice to exit the Tools Menu.
간단한 해결방법입니다.